The KOBOLD URK model flowmeter/monitor works on the basis of the suspended float principle. It is sued for measuring the flow rate in closed line systems. The medium fl;ows from below throigh a glass measuring cone that gets wider on top. Thhus, the float is raised and indicates the respectie flow rate on the scale provided on the measuring cone.
The Kobold flowmeter model UTS works on the basis of the suspended float principle. It comes with a M 18 x 1.5 connection. The inflow of the medium is via 4 mm hole within this connection, whereas the outflow happens via six holes which are concentrically positioned around the inlet hole. This special connection is specifically made for UTS and provided with a special seal. This flowmeter can be optionally supplied with a special adapter G ¼ or ¼" NPT for horizontal installation. The use of this adapter is always recommended because of its special design. Especially in tight places, where conventional devices do not fit best because of their size, the UTS is an automatic choice. The device is suitable for monitoring gas burners (e. g. oxygen, hydrogen, methane, inert gases e.g. MIG welding) due to its low price and possibility of an easy measuring tube exchange. The armature is made of nickel plated brass or stainless steel with impact resistant polystyrene protection bulb.
The KOBOLD flow meter model DRB is used for measuring and monitoring liquids. The device works according the well-known b lade wheel principle. The blade wheel is set in motion by the following medium.
KOBOLD pressure sensors series PDD are cost-effective electronic pressure switches with digital indication of actual pressure. Two switch points, on / off-switch delay and hysteresis, are within the measuring range and are programmable.
A piezzo resistive ceramic sensor is used. The units can be used where high switching accuracy is needed. Long-term stability, repeatability and the compact and robust design makes them ideal for use in OEM applicaionts.
nduction flow meters of the FLONET FH10XX.1 type series are intended for professional application and measurement of flow rates of electrically-conductive liquids in water and heat-supply systems, food-processing and chemical industries. They meet the most demanding requirements on high measurement accuracy, long-term stability and hygienic standard. The converter provides for sensor energizing and processing of the sensor signals, and also offers functions of liquid batching control, detection of empty piping, internal meter status diagnostics, automatic counter cleaning and selection of flow units in data visualization. The flow meters have frequency, pulse and current outputs, as well as interfaces to the HART communication protocol.
Induction flow meters of the type series FLONET FS10XX are intended for professional flow-rate measurements of electrically conductive fluids including abrasive particles. The meters meet most demanding requirements regarding measurement accuracy and long-term parameter stability. Flow-rate measurements in both directions are possible. The flow sensors have excellent wear resistance and its effect on the fluid flow characteristic or pressure in the connecting piping is negligible. The associated electronic unit supplies power to the sensors unit and processes the flow-rate signals. The meters have current and frequency outputs. Communication with external devices is via the Hart communication protocol. The meter display information is in English
Hollow Shaft Encoder, dual channel The IG06 incremental encoder features a low-cost design with through hollow shaft and can be mounted easily.
The IG07 is a robust incremental encoder with through hollow shaft, which is nearly indestructible even under the harshest ambient conditions. Shaft Encoders: Heavy Duty Aluminum Hollow Shaft Encoder, dual channel and zero ref.
Shaft Encoders: Accessory M4 Mounting Flange
Shaft Encoders: Accessory Measuring wheel
Profile IV5800: -Resolution max. 5000 pulses/revolution -IP65 or IP66/IP67 type of protection -Robust bearing construction - -40 °C … +85 °C operating temperature - High shock and vibration resistance
Geared Potentiometers - light duty ratios 0.25 to 550:1 Potentiometer output, solid shaft
Scale 86.8mm, reinforced plastic housing either dust-tight, oil filled or waterproof, scale and pointer, with additional digital counter
Accessories for DE04, DE10, DKE01
Geared Potentiometers - light duty ratios 0.25 to 550:1 Potentiometer output with three CAM switches, solid shaft
Geared Potentiometers - heavy duty ratios 0.25 to 550:1 Potentiometer output
Geared Potentiometers - heavy duty ratios 0.25 to 550:1 4-20mA output
Potentiometer output Wire-actuated encoder with analog output, potentiometric, current source or voltage output, with a measuring length of up to 6000 mm. Easy adjustment of the output signal to the actual measuring length via an integrated gear mechanism.
Current/Voltage output Wire-actuated encoder with analog output, potentiometric, current source or voltage output, with a measuring length of up to 6000 mm. Easy adjustment of the output signal to the actual measuring length via an integrated gear mechanism.
Geared Potentiometers - heavy duty ratios 0.25 to 550:1 4-20 mA output with three CAM switches
The KOBOLD DMH flow meter is used to measure and monitor the volume flow rate of fluids, pulps, pastes and other electrically conductive materials, without loss of pressure. When an electrically conductive passes through a directional magnetic field, a voltage is induced in accordance with Faradays law of induction.