The Calog LOOP II is a high precision, multi-function, hand-held calibrator designed for the process control industry. It’s speciality is milliamp loop powered instruments which it can measure, source and simulate. DC voltage and circuit continuity can also be measured.
Buy Online today
The pyrometer optris CT LT is equipped with one of the world’s smallest infrared sensors with a high optic resolution of 22:1. Additionally, it offers a high variability due to selectable analog outputs as well as several digital interfaces in the electronics box.
The extended version, the pyrometer CTex LT, is additionally equipped with Zener double barriers (for employment in explosion-prone areas).
The DPM5012 is a 5 ½ digit (-199999 to 999999) has uni-polar and bi-polar pulse / frequency inputs for counting, frequency / speed (dual channel), period, flow, timing, totalising and positioning applications. It can be used in conjunction with most standard pulse / frequency generating sensors. Sensor excitation is standard and the output voltage is link selectable. Options include analogue output, alarm setpoints (up to 4 alarms), BCD output. RS-232 or RS-485 communications and many more. The display and analogue output is programmable from the front push buttons. Selected options now feature ‘Plug and Play’ technology allowing options boards to be ordered separately and field fitted when required
The DPM4004 load cell indicator is an easy-to-use precision programmable digital indicator for load cell & strain gauge applications. Inputs to the instrument include load cell input (6 wire) and two digital inputs for remote tare and remote peak hold reset (optional). The excitation includes sense feedback to compensate for cable voltage loss. Digital filtering for better stability and tare function is included as standard. Options include programmable analogue output, set-points (up to four alarms), peak or valley hold, RS-232/485 serial interfaces & more. A feature of these programmable indicators is the calibration method. The instrument can be pre-calibrated without load cell connections for zero & full scale values, & then on-site calibration can be done for deadweight offset & span calibration (single point test weight trim).
The pyrometer optris CSmicro 3M has been designed for a temperature range from 50°C to 600°C. Its special spectral range of 2.3 µm makes it the ideal IR pyrometer for temperature measurement of metallic surfaces starting from 50°C and it allows for measurements through glass.
The small infrared measuring head is optimally suited for installation in limited spaces and subsequently makes possible an especially cost-efficient mechanical process integration.
The CSmicro series can now be operated via the new IR mobile App (Android). The App enables to monitor and analyze infrared temperature measurements on a connected smartphone or tablet.
The pressure transducers of the PD-10L series have been developed to measure differential pressure. These OEM pressure transducers have a single silicon diaphragm in their interior, which is pressurised from both sides and measures the pressure difference directly. This design enables them to measure tiny pressure differences even at an extremely high line pressure.
Profile SDE04:Wire-actuated encoder with a freely programmable electronic digital displayLinear distance measurement up to 1000 mmLong battery lifeEasy battery change without dismantling of the deviceLCD display with 5 digits and special charactersDigit height approx. 8 mmFlexible mounting positionEasy mounting
This pressure transmitter is designed for level measurement in narrow downhole applications where highest accuracy is required. Product Benefits: Only 16 mm diameter, mathematically compensated, programmable, assisting inventory reduction, filtering function 2 ms...30 sec, improved surge protection Pressure measurements can be displayed and recorded on PC or Laptop with help of the software ControlCenterSeries30 (CCS30) and a seriel interface cable. Export of recordings to usual file formats possible. Up to 128 devices can be connected together into a KELLER Bus-system.
The Series 1000 and 2000 are a range of extra large 3 to 5 digit LED array displays, 125 mm digit height, designed to be used in process / temperature / weighing applications where high visibility and distant viewing is required. Using high intensity wide angle LED's in an IP65 enamelled steel housing ensures clear viewing distances of greater than 50 metres. For high ambient temperature conditions, an optional special coated glass window is available.Typical applications include downtime, time and production control in large factories, the indication of load cell inputs / crane overload protection, process signals such as temperature, pressure, level, and AC or DC voltages and currents.For electrical specifications, input signal details, as well as the terminal connector assignments in the Extra Large Display, see the individual indicator operating manuals (e.g. Model 4001). Standard DPM indicators are used and internally fitted for the internal signal conversion for the Extra Large Displays. (Models ending in a 2)
The pressure test pump LR-Cal LPP 40 is used to generate pressure and vacuum for checking, adjusting and calibrating mechanical and electronic pressure measuring instruments by comparative measurements. These pressure tests may be carried out in laboratories, workshop or on site at the measuring point. If the instrument to be tested and a sufficiently accurate reference measuring instrument are connected up to the test pump, the same pressure is applied to the two measuring instruments when the pressure test pump LR-Cal LPP 40 is operated. By comparing the two measure valuses at random pressure values, the accuracy can be verified or the instrument under test can be adjusted. Despite its compact dimensions, the pressure test pump LR-Cal LPP 40 is easy to operate and allows for exact generation of the required test pressures; a change-over switch enables the generation of vacuum as well. The LR-Cal LPP 40 is fitted with a fine adjustment valve for generation of high pressure and a precise adjustment of pressures. The reference instrument is screwd directly on the top of the pump and the unit under test is connected by means of the connection tube incorporating an adapter 1/4" BSP female thread (freely rotating), contained in the scope of delivery.
Universally applicable wire-actuated encoder with measuring lengths of max. 6000 mm, robust construction as well as precise and safe wire guidance, geared up for attaching the most diverse types of rotary encoders with a 58 mm standard flange.
The newly developed optris Xi 80 combines the benefits of infrared cameras and infrared thermometers.
A full 80x80 thermal image eliminates the hunt for the hot spot and tedious positioning required with single spot temperature sensors. The integrated spot finder function will identify the hottest (or coldest) spot in the image and automatically communicate these measurements without an external PC.
A wide range of optics including the new 80° lens equips the Xi 80 to collect and analyze temperature information over a wide target area. The affordable pricing for this unit makes it a realistic alternative to replace existing spot temperature sensors or for OEM applications.
Specifically designed for extended service in sewage lift station environments, the 36 XKY by KELLER features a relatively wide sensing diaphragm yet small overall size. The 36 XKY incorporates a monolithic diaphragm formed from Kynar ® , which combines the non-stick quality of Teflon with superior toughness and abrasion resistance that simplify installation and eliminate the need for bulky and expensive protective cages. The 36XKY utilizes proven piezoresistive silicon measurement technology combined with Kel - ler’s state-of-the-art, microprocessor-based signal conditioning circuitry to provide outstanding accuracy and reliability over a wide compensated temperature range. It is perfectly suited for pump control applications that require standard 2-wire (4...20 mA current loop) or 3-wire (0...10 V) output transmitters. The RS485 interface allows users to scale the analog output to any desired range within the standard pressure range. The 36 XKY is typically suspended into the liquid by a standard Hytrel ® -jacketed cable that is both self-supporting and vented. Optional: Keller’s enhanced lightning protection makes this trans-mitter ideal for installation in areas prone to chronic damage due to transients caused by lightning. Using the Keller CCS30 software and appropriate adapter cable, the user can scale the analog output of the 36 XKY, display and record pressure and temperature readings, and access a variety of other available functions. All of the available functions are defined in the Series 30 Communications Protocol. The CCS30 and Series 30 Communications Protocol are available free of charge from the company website
The IG07 is a robust incremental encoder with through hollow shaft, which is nearly indestructible even under the harshest ambient conditions.Shaft Encoders: Heavy Duty AluminumHollow Shaft Encoder, dual channel
Piezoresistive pressure transmitter for applications in bio-reactors or autoclaves. The transmitter is compensated up to 150 °C and may be operated continuously or sterilised at this level, including the special circuit electronics The transmitters are supplied in absolute or gauge versions, with current or voltage output. The sensing component is a micro-machined silicon pressure chip of high sensitivity. An independent temperature sensor is integrated on the surface of the silicon chip
The CALOG - PRESSURE II’s speciality is pressure measurement and milliamp loop powered instruments which it can measure, source and simulate. DC voltage and circuit continuity can also be measured. Interchangeable pressure sensors enable users to effortlessly connect a wide range of pressure sensors. Simultaneous measurement of pressure and current for I/P testing. Pressure switch test feature ensures accurate and safe calibration of pressure switches. The CALOG - PRESSURE II’s logging facility stores data on the SD card supplied, which is easily downloaded from the SD card to a PC via the on board USB port and useable in most common spreadsheet formats. It’s small size, Lithium Ion battery pack and high precision makes the CALOG - PRESSURE II ideal for industrial field calibration
The Series 46 X combines the ceramic measuring cell for low pressure ranges with the μP-elec- tronics of the digital Series 30 pressure transmitters. The signal values of the pressure- and temperature sensors are determined by a polynomial compensation1). The values can be shown and stored on a PC and can be reprogrammed. A reference tube integrated in the cable connects the referential chamber of the sensor with the ambient pressure.
The MTN/VM220 is a compact,rechargeable, portable handheld Vibration meter designed to conform to ISO10816-3 and operate with a constant current accelerometer providing accurate vibration measurements. Features comprise of the ability to store up to 100 time-stamped readings, including; RMS, peak, peak-peak, crest factor and bearing conditions all on an easy to read vibrant colour LCD display.
The DCX-16 is an autonomous, battery-powered data collector in a stainless steel housing with a very small diameter of only 16 mm. The housing and the pressure sensor element are completely welded in, so sealing rings are eliminated at this point. In applications where a small probe diameter is an advantage, the logger can record the water level (pressure) and the temperature over long periods. As well as the battery compartment with its double seal, the small-diameter (16 mm) submersible sensor includes electronic circuitry featuring the latest microprocessor technology. It records the pressure and temperature of the medium with high measurement accuracy and resolu-tion, and it uses a mathematical model to correct any linearity or temperature errors made by the pressure sensor. High data reliability is guaranteed thanks to the use of a nonvolatile data memory The various configuration options allow the data logger to be adapted to the measuring point so that only specified events will be detected and stored. Event-controlled recording and loginterval recording can be set independently of one another. In addition, installation data and comments on the measuring point can be stored in the logger. Installation is fast and simple with fixing disks of various sizes which can be fitted as options: these match locking units (caps) from different manufacturers for levels of 1” or more (2” or more with light plummet aperture), so measuring points can be implemented at a fraction of the previous cost. Three versions of the data collector are available: DCX-16 The sensor, electronics and battery are accommodated in one housing. To extract data, the data collector must be removed from the measuring point, and the watertight screw cap that allows access to the read-out plug /interface must be unscrewed. The DCX-16 operates with an absolute pressure sensor. In shallow water, when the influence of air pressure fluctuations has to be taken into account, a second logger (barometric logger, obtainable separately) positioned on the surface of the water must be used to record the air pressure progression. The computer software then calculates the differential pressure or the water level by subtracting the two measured data.
Shaft Encoders: AccessoryM2 Mounting flange
Compact geared potentiometers - IP52Potentiometer output
Shaft Encoders: AccessoryBearings for high REVS, (15mm hollow shaft)