The DE10 is a freely programmable and battery-powered position indicator. The position indicator DE04 provides maximum flexibility, since the always same basic device can be parameterized to the desired spindle pitch, display accuracy and reading position in an application-specific manner. Parameterization is conveniently performed via programming software via an external interface.
The DE10P position indicator is a freely programmable and battery-powered position indicator. The DE10P position indicator provides maximum flexibility, since the always same basic device can be parameterized to the desired spindle pitch, display accuracy and reading position in an application-specific manner. The parameterization is performed directly on the device using operating keys.
Absolute position display with communication interface for linear or slide adjustment intuitively guides the operator to the correct machine setting when changing products or changing formats. Readability is optimized for intuitive user prompting: The backlit display clearly shows the setpoint and actual value, and the two LEDs clearly indicate the direction in which the adjustment must be mad.
The turbine flowmeter model DOT consists of a helically shaped turbine rotor supported in two tungsten carbide bearings, the rotor being solid ferritic stainless steel of a grade compatible with the metered liquid, all contained within a housing of non-magnetic stainless steel. A pick off coil having a permanent magnet core is mounted in the housing adjacent to the rotor blade tips such that a magnetic circuit is set up via the rotor blades. Rotation of the rotor varies the reluctance of this magnetic circuit and the flux changes induce a small voltage in the coil, the frequency of which is directly proportional to the rotor speed and therefore proportional to the volumetric flow rate. The effects of increasing viscosity reduce the linear flow range and shifts the k-factor. Further, the effect of viscosity depends on the frequency (RPM of rotors). Therefore, smaller the meter, higher is the effect of viscosity on the linearity curve.
The Series 46 X combines the ceramic measuring cell for low pressure ranges with the μP-elec- tronics of the digital Series 30 pressure transmitters. The signal values of the pressure- and temperature sensors are determined by a polynomial compensation1). The values can be shown and stored on a PC and can be reprogrammed. A reference tube integrated in the cable connects the referential chamber of the sensor with the ambient pressure.
The MSC500 magnetic sensor has a large, multi-color status LED that makes commissioning and function monitoring easier for users. The correct distance between the gage and the sensor can be visually monitored. With the plug connection directly on the sensor head, the MSC500 is also suitable for use in very confined spaces. As a result installation is fast and simple, which naturally means lower costs. In addition, the MSC500 sensor includes all digital square wave signals. This enables evaluation of the A/B signals, the inverted signals and the periodic index signals with the same sensor.
In the high-precision level probe of the 26X series, the temperature dependence and nonlinearity are precisely compensated for in the microcontroller by means of a mathematical model. In addition to the RS485 interface, the measurement results can also be output via the integrated D/A converter as a rangeable analog signal. Extended lightning protection is also available as an option.
Compact wire-actuated encoder with a max. measurement length of 2000 mm and an analog output.
Compact wire-actuated encoder for rotary encoders with max. 36 mm diam. flange
Very robust wire-actuated encoder in compact design for numerous applications including crane construction, stage construction, warehousing technology, etc., with a measuring length up to 3000 mm. Easy, universally changeable installation.
The new KOBOLD flowmeter Type MIK is used for measuring and monitoring the smaller and medium-sized flows of conductivity liquids in pipes. The device operates according to the electromagnetic measurement principle. According to Faraday’s Law of magnetic induction, a voltage is induced in a conductor moving through a magnetic field. The electrically conductive measuring agent acts as the moved conductor. The voltage induced in the measuring agent is proportional to the flow velocity and is, therefore, a value for the volumetric flow. The flowing media must have a minimum conductivity. The induced voltage is picked up by two sensing electrodes that are in contact with the measuring agent and sent to the measuring amplifier. The flow rate will be calculated based on the cross-sectional area of the pipe. The measurement is not depending on the process liquid and its material properties such as density, viscosity and temperature. The device may be equipped with a switch, frequency or analogue output. Moreover, there is a compact electronic system to be selected from, which contains a switch and an analogue output. The device series is completed by optionally obtainable dosing and counter electronic system. The counter electronics system shows the current flow rate on the first line of the display and shows the partial or overall volume on the second line. A dosing electronic system controls simple filling duties and also measures the flow rate, overall volume and filling volume. The analogue output and two relay outputs can be utilised for the further processing of signals.
Media
Applications
Flow monitoring, Flow measuring, dosing and counting for:
In the 23SX series high-precision pressure transmitters, temperature dependencies and non-linearity are precisely compensated for by means of a mathematical model in the microcontroller. In addition to the RS485 interface with Modbus RTU protocol, there is also the option of outputting the measurement results as a scalable analogue signal via the integrated D/A converter. The fully welded construction without internal seals is suitable for dynamic applications. Only stainless steel is in contact with the media.
The pressure transmitters of the 21C series with ratiometric 0,5...4,5V output combine chip-in-oil measuring cells with conventional electrical connections and pressure connections, making them ideal for industrial use. The transmitters are extremely resistant to environmental influences and deliver accurate measurement results over a temperature range of -40 °C to 125 °C.