Profile MSK210: Max. resolution 25 μm max. resolution 0.045° with MR200 or MBR200 (100 poles) Repeat accuracy ±0.025 mm Repeat accuracy of ±1 increment Works with magnetic tape MB200/1 Works with MR200 magnetic ring, MBR200 magnetic tape ring Reading distance ≤1 mm Reading distance ≤0.8 mm Max. 4600 pulses/revolution with MBR200 (230 poles)
Profile MSK200/1: Max. resolution 0.4 μm Works with MB200/1 magnetic tape, MR200 magnetic ring, MBR200 magnetic tape ring Reading distance ≤1 mm IP67 protection category Optionally with reference point R or flexible reference marks FR Interface LD Interface RS485 with Panasonic or Yaskawa protocol
Profile LE200: Robust metal housing Status LED display sin/cos output 1 VSS Signal period 2000 μm Scale MB200/1 Insensitive to dust, shavings, humidity, etc.
The MSAC501 magnetic sensor serves truly absolute roto measurement, e.g., on large 3-phase current or torque motors.The sensor has the standardized SSI or 485 interfaces. Optionally, an LD output can be selected for incremental signal output. Circumferential speeds of 25 m/sec (incremental) or 5 m/sec (absolute) can be attained.
A combination of the MSAC506 magnetic sensor and the MRAC506 magnetic ring forms a system for absolute angle measurement. The MSAC506 sensor has an SSI interface with a resolution of 12 … 16 bit. There is also an analogue output (1 VSS) with 64 periods for dynamic position tracking. The sensor has an LED for distance monitoring
Profile MSK400/1: Max. resolution 1 mm Repeat accuracy of ±1 increment Works with magnetic tape MB400 Reading distance ≤4 mm
Profile MSK2000: Linear resolution 0.25 mm Repeat accuracy of ±1 increment Operating voltage 5 or 24 V Works with magnetic tape MB2000 Reading distance ≤10 mm
Profile MSK4000: Max. resolution of 0.25 mm Repeat accuracy ±2 increments (max. ±0.5 mm) Works with magnetic tape MB4000 Reading distance ≤20 mm
Very robust wire-actuated encoder in compact design for numerous areas of application including crane construction, stage construction, warehousing technology, etc., up to a measuring length of 6000 mm, with signal output in redundant design.
LR-Cal LPP 60-T Description Pressure comparator LR-Cal LPP 60-T in use with reference pressure gauge LR-Cal TLDMM 2.0The pressure test pump LR-Cal LPP 60-T is used to generate pressures and vacuum for checking, adjusting and calibrating mechanical and electronic pressure measuring instruments by comparative measurements. These pressure tests may be carried out in laboratories, workshop or on site at the measuring point. If the instrument under test and a sufficiently accurate reference measuring instrument (e.g. electronic pressure calibrator LR-Cal LPC 300 or LR-Cal LPC 200, accuracy ±0.025% FS) are connected to the LR-Cal LPP 60-T, the same pressure pressure resp. vacuum is applied to the two instruments when the pump is operated. Despite its compact dimensions, the pneumatic pressure comparator LR-Cal LPP 60-T is easy to operate and allows for exact generation of the required test pressures. A change-over switch enables the generation of vacuum as well. The LR-Cal LPP 60-T is fitted with a fine adjustment valve for the precise adjustment of pressures. The reference instrument is screwed directly on to the top of the pump and the unit under test is connected by means of a connection tube incorporating an adapter 1/4" BSP rotating female (optional 1/4" NPT female) port.
Proven primary pressure standard Deadweight Tester / Pressure Balances are the most accurate instrument available on the market for the calibration of electronic or mechanical pressure measuring instruments. The direct measurement of the pressure (p = F / A), as well as the use of high-quality materials enable a very small measurement uncertainty, in conjunction with an excellent long-term stability of 5 years (recommended in accordance with German Calibration Service DAkkS). The deadweight tester / pressure balance has therefore been used for years in factory and calibration laboratories in national institutes, research laboratories and in industry. Stand-alone operation Due to its integrated pressure generation and the pure mechanical measuring principle, the model LR-Cal LDW-P is ideal for on-site use for maintenance and service. Basic principle Pressure is defined as the quotient of force and area. The core component of the model LR-Cal LDW-P is therefore a very pecisely manufatured piston-cylinder-system, which is loaded with masses in order to generate the individual test points. The masses applied are proportional to the target pressure and this is achieved through optimally graduated weights. As standard, these masses are manufactured to the standard gravity (9.80665 m/s²), though the can be manufactured to a specific location (gravity) and also DAkkS-calibrated. Easy operation Depending on the instrument version the pressure is set via an integrated pump or via an external pressure supply by the use of control valves. For fine adjustment a very precisely adjustable spindle pump with a precision spindle running only within the pump body is mounted. As soon as the measuring system reaches equilibrium, there is a balance of forces between the pressure and the mass load applied. The excellent quality of the system ensures that this pressure remains stable over several minutes, so that the pressure value for comparative measurements can be read without any problems, or also so that more complex adjustments can be carried out on the item under test.
The DPM5012 is a 5 ½ digit (-199999 to 999999) has uni-polar and bi-polar pulse / frequency inputs for counting, frequency / speed (dual channel), period, flow, timing, totalising and positioning applications. It can be used in conjunction with most standard pulse / frequency generating sensors. Sensor excitation is standard and the output voltage is link selectable. Options include analogue output, alarm setpoints (up to 4 alarms), BCD output. RS-232 or RS-485 communications and many more. The display and analogue output is programmable from the front push buttons. Selected options now feature ‘Plug and Play’ technology allowing options boards to be ordered separately and field fitted when required
As a universal indicator, the instrument is fully programmable from the front push buttons for decimal point selection, scaling, positive or negative logic, parallel or multiplexed BCD input, Gray Code input & Binary input. The panel mount housing is a standard DIN 48mm x 96mm size. Applications include displays for PLC outputs for process control, & displays for absolute shaft encoders. Options include programmable analogue output, one, two, three or four alarms, RS-232 output etc. The analogue output is programmable from the front push buttons. Selected options now feature ‘Plug & Play’ technology, allowing option boards to be ordered separately & field fitted when required.
The Model 4011 (4 digit) & Model 5011 (5½ digit) LED serial input indicators are used for remote display of serial data of numeric & alpha-numeric format. These indicators are ideal for applications where multiple slave display units are required. The indicators utilise DPM's ASCIIbus protocol for easy implementation into almost any system. The indicators come with a choice of either RS-232 input or RS-485 input for bus systems. The display may be set to flash on and off whenever the indicator does not receive valid refresh data within a specified time period. Options include programmable analogue output, one, two, three or four alarms, BCD output and other options. The analogue output option is rangeable from the front pushbuttons. Selected options now feature ‘Plug & Play’ technology, allowing option boards to be ordered separately & field fitted when required.
The quick exposure time of only 90 μs makes the high speed IR thermometer CT 4M the perfect sensor for measuring fast processes. Due to its short measuring wavelength and a temperature range from 0°C to 500 °C, the pyrometer optris CT 4M, is suitable for measurements of metals, metal oxides, ceramics or materials with unknown or changing emissivity.
The electronics box of the measuring device allows a flexible terminal device through selectable analog outputs as well as various optional digital interfaces.
5103 transducers are double-ended, centre-loaded shear beam load cells. The 5103 is constructed of nickel-plated alloy steel. These products are suitable for tank weighing systems, low-cost weighbridges, and axle weighers. A reliable sealing is ensured by the proprietary TRANSEAL potting compound and additional mechanical protection of the strain gage area. A specially designed mounting arrangement is available, providing the ideal solution for vessel/tank weighing.
The Model 9103 is a double-ended, centre-loaded shear beam type load cell constructed of stainless steel.
This product is suitable for tank weighing systems, low-cost weighbridges and axle weighers.
A reliable sealing is ensured by the proprietary TRANSEAL potting compound and additional mechanical protection of the strain gage area.
A specially designed mounting arrangement is available, providing the ideal solution for vessel/tank weighing.
The Load cell HPS is a unique fully welded all stainless steel single point (moment insensitive) load cell. This product is suitable for low capacity platform scales, multi-head packaging machines, check weighers, loss-in-weight feeders, belt scales, and general process weighing applications. The unique construction ensures that this product can be used successfully in harsh environments found in the food, chemical, and allied industries. This product meets the stringent Weights and Measures requirements throughout Europe.
The Load cell ASC2 is a single column, stainless steel compression load cell fully compatible with original Model ASC. This product is suitable for use in road and rail weighbridges and process weighing applications. The fully welded construction and built-in surge protection ensures that this product can be used successfully in many harsh environments. This load cell meets the stringent Weights and Measures requirements throughout Europe and the Americas
The KSR is a sealed, single column, compression load cell. This product is suitable for high capacity platform scales and level control or process weighing in general. A reliable sealing and mechanical protection of the strain gage area is ensured by the use of stainless steel diaphragms and a housing which are cemented to the measuring element.
Profile LEC200: Repeat accuracy max. ±2 μm Max. resolution 0.2 µm (LD output circuit) Reading distance 0.1 … 1 mm Works with magnetic tape MB200/1 Signal period 2000 μm Output circuit sin/cos or LD Function and status display LEDs