Mechanical data
Feature |
Technical data |
Additional information |
Housing |
reinforced plastic |
|
Wire design |
ø0.45 mm |
rustproof stainless steel, plastic-coated
|
|
ø0.45 mm |
rustproof stainless steel |
Extension force |
≥2 N |
|
Measured distance/ rope drum revolution |
100 mm |
|
Cable length |
≤30 m |
P10 + MWI encoder type
|
|
≤20 m |
MWU encoder type
|
Weight |
~0.2 kg |
|
Electrical data
Encoder potentiometer
Feature |
Technical data |
Additional information |
Power rating |
1.5 W at 70 °C |
|
Resistance |
10 kΩ |
|
Resistance tolerance |
±5 % |
|
Linearity tolerance |
±0.25 % |
|
|
±0.1 % |
encoder type MWI/0,1 |
Transducer, power output
Feature |
Technical data |
Additional information |
Operating voltage |
24 V DC ±20 % |
at ≤500 Ω load
|
Output current |
4 … 20 mA |
|
Transducer, voltage output
Feature |
Technical data |
Additional information |
Operating voltage |
15 … 28 V DC |
at 3 mA, no load
|
Output voltage |
0 … 10 V DC |
|
Load |
≤15 mA |
|
*
Measurement transducers permit optimum adjustment of the output current and output voltage to the measuring range. The measurement transducer is pre-set at the works so that an output signal of 4 … 20 mA (MWI) or 0 … 10 V DC (MWU) is available.
System data
Feature |
Technical data |
Additional information |
Repeat accuracy |
±0.15 mm |
|
Travel speed |
≤800 mm/s |
|
Ambient conditions
Feature |
Technical data |
Additional information |
Ambient temperature |
-10 … 80 °C |
without transducer
|
|
0 … 50 °C |
with transducer
|
Protection category |
IP50 (encoder part potentiometer)
|
EN 60529 |
|
IP54 (incremental) |
EN 60529 |