The HygroSmart HS3 is an accurate, stable and user configurable probe designed to provide reliable humidity measurement for process control in a wide range of applications. The HS3 probe features an interchangeable sensor to ensure minimal process downtime and low cost of ownership.
The MDM25 is a portable, battery-operated handmeter, and is available with a number of different probe confi gurations. It displays relative humidity, temperature and one calculated value, making this hand-held hygrometer suitable for a wide range of applications. The user can choose to display either °C or °F.
The PC 33 & 52 series offers a comprehensiverange of relative humidity probes for accurate, stable and repeatable measurements. Available with analog output signals, the PC series can be installed in a wide variety of applications.
The PC series offers a comprehensive range of relative humidity probes for accurate, stable and repeatable measurements. Available with analogue or digital output signals, the PC series can be installed in a wide variety of applications.
The DT722 is a ruggedindustrial relative humidity and temperature transmitter designed for process applications where accurate, stable measurement and control of humidity and temperature is required
The micro processor controland multi-point calibration gives the PCMini52 RH probe excellent performance in terms of accuracy and linearity. The mini probe can provide two linear analog outputs for temperature and relative humidity, dew point, absolute humidity or wet bulb temperature.
The LR-Cal FLUID 200 is a portable stirred liquid bath (temperature calibrator). The instrument is suitable for calibrating temperature sensors and thermometers of all sizes, diameters and shapes, without the need of specifically drilled blocks. The calibration baths are perfect for checking and calibration of glass thermometers.
The portable dry metal block temperature calibrator LR-Cal SOLAR is temperature source and reference instrument in one device, for checking and calibrating of all kind of temperature instruments, such as thermometer, RTDs, Thermocouples, Temperature switches, etc.The ceramic equalizing block, whose large size suits the external dimensions, ensures a proper heat transmission as well as optimal stability and uniformity values. It's interchangeability makes it possible to test sensors of various lengths, with diameters ranging from 1 mm up to 26 mm.The device is equipped with a counter-current forced air cooling system, which keeps the temperature in the upper part of the well low. This feature allows checking also of very short probes, without heating the connecting head or the handgrip.
The LR-Cal FLUID 100 is a portable stirred liquid bath (temperature calibrator, micro bath). The instrument is suitable for calibrating temperature sensors and thermometers of all sizes, diameters and shapes, without the need of specifically drilled blocks. The calibration baths are perfect for checking and calibration of glass thermometers.
The LR-Cal PULSAR-80Cu temperature calibrator is a compact instrument used to calibrate temperature probes, thermometers, thermostats and temperature mesuring sensors. The considerable size makes it suitable for calibrations of probes with large insertion lengths.The LR-Cal PULSAR-80Cu temperature calibrator consists of a metal block (80 mm diameter x 300 mm depth) heated by a resistance which winds around the outer surface of the block. A hole with 60 mm diameter and 275 mm depth is made in the block for the apprpriate reduction inserts.The LR-Cal PULSAR-80Cu is equipped with a counter-current forced air cooling system which keeps the temperature at the upper part of the well low. This system enables to check even very short probes, without heating the connecting head or the handgrip.The instrument is equipped with a PID microprocessor controller with a resolution up to 0.01°C, allowing the setting of the standard of measurement to °C, °F or K and programming of ascent or descent ramps, and storage of thermostats' operative temperature.
The portable dry metal block temperature calibrator model LR-Cal PULSAR-35Cu is used as temperature source and reference instrument for checking and calibrating of all kind of temperature measuring instruments, e.g. thermometer, thermostats, etc.
The portable dry metal block temperature calibrator model LR-Cal QUARTZ-35 is used as temperature source and reference instrument for checking and calibrating of all kind of temperature measuring instruments, e.g. thermometer, thermostats, etc.
This compact and innovative dry block temperature calibratior is expecially designed for field applications, robust and able to maintain high accuracy and stability in severe conditions such as offshore rigs and on board of vessels. The self contained unit is very compact, portable and light weight. The innovative forced air ventilation of model LR-Cal PYROS-375 greatly reduce the cooling time and prevents the sensors under test being exposed to excessive heating.
This compact and innovative dry block temperature calibrator is especially designed for field applications, robust and able to maintain high accuracy and stability in severe conditions such as offshore rigs and on board of vessels. The self contained unit is very compact, portable and light weight. The innovative forced air ventilation of model LR-Cal PYROS-650 greatly reduce the cooling time and prevents the sensors under test from being exposed to excessive heating.
This compact and innovative dry block temperature calibrator is especially designed for field applications, robust and able to maintain high accuracy and stability in severe conditions such as offshore rigs and on board of vessels. The self contained unit is very compact, portable and light weight. The innovative forced air ventilation of model LR-Cal PYROS 140-2L greatly reduce the cooling time and prevents the sensors under test from being exposed to excessive heating.
This compact and innovative dry block temperature calibrator is especially designed for field applications, robust and able to maintain high accuracy and stability in severe conditions such as offshore rigs and on board of vessels. The self contained unit is very compact, portable and light weight. The innovative forced air ventilation of model LR-Cal PYROS 140-1L greatly reduce the cooling time and prevents the sensors under test from being exposed to excessive heating.
Proven primary pressure standard Deadweight Tester / Pressure Balances are the most accurate instrument available on the market for the calibration of electronic or mechanical pressure measuring instruments. The direct measurement of the pressure (p = F / A), as well as the use of high-quality materials, enable a very small measurement uncertainty, in conjunction with excellent long-term stability of 5 years (recommended in accordance with German Calibration Service DKD/DAkkS). The deadweight tester/pressure balance has therefore been used for years in factory and calibration laboratories in national institutes, research laboratories and in industry.
Stand-alone operation Due to its integrated pressure generation and the pure mechanical measuring principle, the model LR-Cal LDW-HK is ideal for on-site use for maintenance and service.
Basic principle Pressure is defined as the quotient of force and area. The core component of the model LR-Cal LDW-HK is therefore a very precisely manufactured piston-cylinder-system, which is loaded with masses in order to generate the individual test points. The masses applied are proportional to the target pressure and this is achieved through optimally graduated weights. As standard, these masses are manufactured to the standard gravity (9.80665 m/s²), though they can be manufactured to a specific location (gravity) and also UKAS (DAkkS)-calibrated.
Easy operation The integrated dual-area spindle pump enables rapid filling of the test system and smooth pressure generation up to 1,200 bar. At the same time, the precisely adjustable spindle pump also serves for fine pressure adjustment. A control schematic for pressure generation on the instrument base facilitates quick and easy operation.
As soon as the measuring system reaches equilibrium, there is a balance of forces between the pressure and the mass load applied. The excellent quality of the system ensures that this pressure remains stable over several minutes, so that the pressure value for comparative measurements can be read without any problems, or also so that more complex adjustments can be carried out on the item under test.
Compact instrument design The LR-Cal LDW-HK is also particularly notable for its compact dimensions, which are not altered during operation since the spindle runs within the pump body. With its compact dimensions, the exceptionally robust ABS plastic housing and the low weight associated with these, the LR-Cal LDW-HK is also particularly suited to on-site applications.
Proven primary pressure standard Deadweight Tester / Pressure Balances are the most accurate instrument available on the market for the calibration of electronic or mechanical pressure measuring instruments. The direct measurement of the pressure (p = F / A), as well as the use of high-quality materials enable a very small measurement uncertainty, in conjunction with an excellent long-term stability of 5 years (recommended in accordance with German Calibration Service DKD/DAkkS). The deadweight tester / pressure balance has therefore been used for years in factory and calibration laboratories in national institutes, research laboratories and in industry. Stand-alone operation Due to its integrated pressure generation and the pure mechanical measuring principle, the model LR-Cal LDW-H is ideal for on-site use for maintenance and service. Basic principle Pressure is defined as the quotient of force and area. The core component of the model LR-Cal LDW-H is therefore a very pecisely manufatured piston-cylinder-system, which is loaded with masses in order to generate the individual test points. The masses applied are proportional to the target pressure and this is achieved through optimally graduated weights. As standard, these masses are manufactured to the standard gravity (9.80665 m/s²), though the can be manufactured to a specific location (gravity) and also DAkkS-calibrated. Easy operation In the stable instrument base, the integrated priming pump and the 250 ml tank enable large test volumes to be easily filled and pressurised. For further pressure increases and find adjustment, a very precisely-controllable spindle pump is fitted, which only runs within the pump body. As soon as the measuring system reaches equilibrium, there is a balance of forces between the pressure and the mass load applied. The excellent quality of the system ensures that this pressure remains stable over several minutes, so that the pressure value for comparative measurements can be read without any problems, or also so that more complex adjustments can be carried out on the item under test
LR-Cal LPP 60-T Description Pressure comparator LR-Cal LPP 60-T in use with reference pressure gauge LR-Cal TLDMM 2.0The pressure test pump LR-Cal LPP 60-T is used to generate pressures and vacuum for checking, adjusting and calibrating mechanical and electronic pressure measuring instruments by comparative measurements. These pressure tests may be carried out in laboratories, workshop or on site at the measuring point. If the instrument under test and a sufficiently accurate reference measuring instrument (e.g. electronic pressure calibrator LR-Cal LPC 300 or LR-Cal LPC 200, accuracy ±0.025% FS) are connected to the LR-Cal LPP 60-T, the same pressure pressure resp. vacuum is applied to the two instruments when the pump is operated. Despite its compact dimensions, the pneumatic pressure comparator LR-Cal LPP 60-T is easy to operate and allows for exact generation of the required test pressures. A change-over switch enables the generation of vacuum as well. The LR-Cal LPP 60-T is fitted with a fine adjustment valve for the precise adjustment of pressures. The reference instrument is screwed directly on to the top of the pump and the unit under test is connected by means of a connection tube incorporating an adapter 1/4" BSP rotating female (optional 1/4" NPT female) port.
Proven primary pressure standard Deadweight Tester / Pressure Balances are the most accurate instrument available on the market for the calibration of electronic or mechanical pressure measuring instruments. The direct measurement of the pressure (p = F / A), as well as the use of high-quality materials enable a very small measurement uncertainty, in conjunction with an excellent long-term stability of 5 years (recommended in accordance with German Calibration Service DAkkS). The deadweight tester / pressure balance has therefore been used for years in factory and calibration laboratories in national institutes, research laboratories and in industry. Stand-alone operation Due to its integrated pressure generation and the pure mechanical measuring principle, the model LR-Cal LDW-P is ideal for on-site use for maintenance and service. Basic principle Pressure is defined as the quotient of force and area. The core component of the model LR-Cal LDW-P is therefore a very pecisely manufatured piston-cylinder-system, which is loaded with masses in order to generate the individual test points. The masses applied are proportional to the target pressure and this is achieved through optimally graduated weights. As standard, these masses are manufactured to the standard gravity (9.80665 m/s²), though the can be manufactured to a specific location (gravity) and also DAkkS-calibrated. Easy operation Depending on the instrument version the pressure is set via an integrated pump or via an external pressure supply by the use of control valves. For fine adjustment a very precisely adjustable spindle pump with a precision spindle running only within the pump body is mounted. As soon as the measuring system reaches equilibrium, there is a balance of forces between the pressure and the mass load applied. The excellent quality of the system ensures that this pressure remains stable over several minutes, so that the pressure value for comparative measurements can be read without any problems, or also so that more complex adjustments can be carried out on the item under test.
The pressure test pump LR-Cal LPP 700 is used to generate pressure for checking, adjusting and calibrating mechanical and electronic pressure measuring instruments by comparative measurements. These pressure tests may be carried out in laboratories, workshop or on site at the measuring point. If the instrument to be tested and a sufficiently accurate reference measuring instrument are connected up to the test pump, the same pressure is applied to the two measuring instruments when the pressure test pump LR-Cal LPP 700 is operated. By comparing the two measure valuses at random pressure values, the accuracy can be verified or the instrument under test can be adjusted. Despite its compact dimensions, the pressure test pump LR-Cal LPP 700 is easy to operate and allows for exact generation of the required test pressures The LR-Cal LPP 700 is fitted with a fine adjustment valve for a precise adjustment of pressures. The reference instrument is screwd directly on the top of the pump and the unit under test is connected by means of the connection tube incorporating an adapter 1/4" BSP female thread (freely rotating), contained in the scope of delivery.
The pressure test pump LR-Cal LPP 40 is used to generate pressure and vacuum for checking, adjusting and calibrating mechanical and electronic pressure measuring instruments by comparative measurements. These pressure tests may be carried out in laboratories, workshop or on site at the measuring point. If the instrument to be tested and a sufficiently accurate reference measuring instrument are connected up to the test pump, the same pressure is applied to the two measuring instruments when the pressure test pump LR-Cal LPP 40 is operated. By comparing the two measure valuses at random pressure values, the accuracy can be verified or the instrument under test can be adjusted. Despite its compact dimensions, the pressure test pump LR-Cal LPP 40 is easy to operate and allows for exact generation of the required test pressures; a change-over switch enables the generation of vacuum as well. The LR-Cal LPP 40 is fitted with a fine adjustment valve for generation of high pressure and a precise adjustment of pressures. The reference instrument is screwd directly on the top of the pump and the unit under test is connected by means of the connection tube incorporating an adapter 1/4" BSP female thread (freely rotating), contained in the scope of delivery.
The pressure test pump LR-Cal LPP 08 is used to generate pressure and vacuum for checking, adjusting and calibrating mechanical and electronic pressure measuring instruments by comparative measurements in the low-pressure and vacuum range. The pressure tests may be carried out in laboratories, workshops or on-site at the measuring point.
If the instrument to be tested and a sufficiently accurate reference measuring instrument are connected up to the pressure test pump, the same pressure is applied to the two measuring instruments when the pump is operated. By comparing the two measure values at random pressure values, the accuracy can be verified or the unit under test can be adjusted.
The LR-Cal LPP 08 is a pneumatic pressure test pump for low-pressure ranges up to 8 bar with a change-over switch to vacuum down to -850 mbar. Despite its compact dimensions, the pressure test pump is easy to operate and allows for the exact generation of the required test pressures. The maximum pressure or vacuum achievable depends on the attached test volume. The smooth-running pressure generation and the integrated fine adjustment valve allow a safe and precise setting of very small positive resp. negative pressure values in the range of mbar.
The unit under test and the reference instrument can be easily connected with the supplied accessories.
Included in the scope of standard delivery:
The vacuum test pump LR-Cal 2941 is used to generate vacuum (negative pressure) for checking, adjusting and calibrating mechanical and electronic pressure measuring instruments by comparative measurements. These vacuum tests may be carried out in laboratories, workshop or on site at the measuring point. If the instrument to be tested and a sufficiently accurate reference measuring instrument are connected up to the test pump, the same vacuum is applied to the two measuring instruments when the vacuum test pump LR-Cal 2941 is is operated. By comparing the two measure valuses at random pressure values, the accuracy can be verified or the instrument under test can be adjusted. Despite its compact dimensions, the vacuum test pump LR-Cal 2941 is easy to operate and allows for exact generation of the required test vacuum. The LR-Cal 2941 is fitted with a fine adjustment valve for precise adjustment of vacuum. Pressure connection is made with 4 mm hose, a T-piece wich quick-coupling and a piece of hose is included in standard delivery.