The infrared video thermometer optris CTvideo 3M is perfectly suited for low-temperature measurement of metals and composite materials starting from 50°C. Parallel use of the video module and the laser sight allow for an easy and exact measuring field marking even if the measuring object is located in hard-to-access areas
Due to its short measuring wavelength the ratio pyrometer optris CTratio 1M is especially suited for measurement of extremely high metal temperatures and the very short response time allows for surveillance of very fast processes.
The ratio pyrometer is largely resistant against dust, steam and dirty observation windows. This allows for an accurate measurement in cases of window soiling of up to 90 percent. The pyrometer additionally measures reliably in cases where the measuring object only covers 5 percent of the measuring point or moves very fast.
Rugged, electrically isolated sensing head and fiber optic cable for ambient temperatures up to 315 °C without cooling.
Due to its short measuring wavelength the ratio pyrometer optris CTratio 2M is especially suited for measurement of extremely high metal temperatures and its very short response time allows for surveillance of very fast processes.
Rugged, electrically isolated sensing head and fiber optic cable for ambient temperatures up to 315 °C without cooling
The infrared laser thermometer optris CTlaser F2 offers a special measuring wavelength for temperature measurement of CO2 flame gases. This makes it optimally suited for e.g. combustion processes, garbage incineration, or processes in chemical reactors.
The IR thermometer’s temperature range covers temperatures from 200°C up to 1,650°C, while the stainless steel measuring head is heat-resistant up to 85°C without additional cooling. Optional cooling and protection equipment is available, ensuring exact temperature measurement even in rough surroundings.
The infrared thermometer optris CTlaser F6 is an upgraded version of the pyrometer optris CTlaser F2. It has also been designed for temperature measurement of CO flame gasses, e.g. in combustion processes, in garbage incineration, or in processes in chemical reactors.
The pyrometer measures temperatures precisely between 200°C and 1,650°C. Due to the measuring head being made of stainless steel, it is heat-resistant up to 85°C without additional cooling. Also, optional cooling and protection equipment is available, ensuring exact temperature measurement even in rough surroundings.
The infrared thermometer optris CTlaser G5 has been specifically designed for measurement of glass temperatures, especially for container glass, lightbulb production, vehicle glass production as well as in the manufacturing of solar cells. Last but not least, the IR thermometer optris CTlaser G5 allows for temperature measurement of smallest objects of 1 mm from a distance of 70 mm.
The IR thermometer optris CSlaser G5 HF offers very quick response times and is thus perfectly suited for fast processes.
The infrared thermometer optris CTlaser G7 is perfectly suited for precise temperature measurement of ultra-thin glass surfaces. It offers a broad temperature range from 100 °C up to 1200 °C and can be employed in temperatures of up to 85°C without additional cooling.
The IR thermometer for measurements of plastic foils and glass temperatures is capable of targeting smallest objects of 1.6 mm (0.06 in) in a distance of 70 mm (2.76 in). Its standardized two-wire interface additionally allows for a reliable transfer of measurement data and easy integration into a PLC.
The DPM4001, four digit LED Universal Process Indicator, can be applied to most process variables with analogue & digital inputs. This high accuracy, high-quality panel meter is designed for accurate measurement & display of pressure, level, flow, frequency, DC voltages or currents & revolutions per minute. Options include linearisation, analogue output and set-points up to a total of four. The display & analogue output is rangeable from the front pushbuttons. Excitation is standard & is link selectable for 2-wire / 3-wire transmitters, encoders & potentiometer input.
These high accuracy, high quality LED indicators are used for universal process, counting and frequency applications. The -T option includes process integration / totalisation function. These indicators can be applied to most process variables with analogue & digital inputs, such as the measurement & display of pressure, level, flow, frequency, DC voltages or currents & revolutions per minute. Options include linearisation, analogue output and set-points up to a total of four. The display & analogue output is rangeable from the front pushbuttons. Excitation is standard & is link selectable for 2-wire / 3-wire transmitters, encoders & potentiometer input. Selected options feature ‘Plug & Play’ technology, allowing option boards to be ordered separately & field fitted when required.
The DPM4015, 4 digit (-1999 to 9999), LED Dual Channel Process Indicator can be applied to many applications which require a dual input and a single display eg. temperature and humidity monitoring. Each channel is individually setup for zero , span, input type and more. The unit boasts a number of useful mathematical functions such as addition, subtraction, multiplication and division. The display as well as alarms, analogue out and peak hold can be selected using channel A, Channel B and the above mentioned mathematical functions. Options include linearisation, analogue output and set-points up to a total of four. Excitation is standard and link selectable for 2-wire / 3-wire transmitters and a potentiometer input. Selected options now feature ‘Plug & Play’ technology, allowing option boards to be ordered separately & field fitted when required
The DPM5015, 5 ½ (-199999 to 199999), LED Dual Channel Process Indicator can be applied to many applications which require a dual input and a single display eg. temperature and humidity monitoring. Each channel is individually setup for zero , span, input type and more. The unit boasts a number of useful mathematical functions such as addition, subtraction, multiplication and division. The display as well as alarms, analogue out and peak hold can be selected using channel A, Channel B and the above mentioned mathematical functions. Options include linearisation, analogue output and set-points up to a total of four. Excitation is standard and link selectable for 2-wire / 3-wire transmitters and a potentiometer input. Selected options now feature ‘Plug & Play’ technology, allowing option boards to be ordered separately & field fitted when required.
The Model 5016, is a 2 by 3 Digit (-99 - 199) LED Dual Channel Process Indicator which can be applied to many applications which require a dual input and a dual display eg. Temperature and humidity monitoring. Each channel is individually setup for zero , span, input type and more. The display as well as alarms, analog out, peak hold can be selected using channel A or Channel B. Options include linearisation, analogue output and set-points up to a total of four. Excitation is standard and is link selectable for 2-wire / 3-wire transmitters and a potentiometer input. Selected options now feature ‘Plug & Play’ technology, allowing option boards to be ordered separately & field fitted when required.
The DPM5600, a six digit LED Universal Process Indicator can be applied to most process variables with analogue & digital inputs. This high accuracy, high-quality panel meter is designed for accurate measurement & display of pressure, level, flow, frequency, DC voltages or currents & revolutions per minute. Options include linearisation, analogue output and set-points (up to a total of four). The display & analogue output is programable from the front push buttons. Excitation is standard & link selectable for 2-wire / 3-wire transmitters, encoders & potentiometer input. Selected options now feature ‘Plug & Play’ technology, allowing option boards to be ordered separately & field fitted when required.
These high accuracy, high quality LED indicators are used for universal process, counting and frequency applications. The -T option includes process integration / totalisation function. These indicators can be applied to most process variables with analogue & digital inputs, such as the measurement & display of pressure, level, flow, frequency, DC voltages or currents & revolutions per minute. Options include linearisation, analogue output and set-points up to a total of four.
The DPM5012 is a 5 ½ digit (-199999 to 999999) has uni-polar and bi-polar pulse / frequency inputs for counting, frequency / speed (dual channel), period, flow, timing, totalising and positioning applications. It can be used in conjunction with most standard pulse / frequency generating sensors. Sensor excitation is standard and the output voltage is link selectable. Options include analogue output, alarm setpoints (up to 4 alarms), BCD output. RS-232 or RS-485 communications and many more. The display and analogue output is programmable from the front push buttons. Selected options now feature ‘Plug and Play’ technology allowing options boards to be ordered separately and field fitted when required
As a universal indicator, the instrument is fully programmable from the front push buttons for decimal point selection, scaling, positive or negative logic, parallel or multiplexed BCD input, Gray Code input & Binary input. The panel mount housing is a standard DIN 48mm x 96mm size. Applications include displays for PLC outputs for process control, & displays for absolute shaft encoders. Options include programmable analogue output, one, two, three or four alarms, RS-232 output etc. The analogue output is programmable from the front push buttons. Selected options now feature ‘Plug & Play’ technology, allowing option boards to be ordered separately & field fitted when required.
The Model 4011 (4 digit) & Model 5011 (5½ digit) LED serial input indicators are used for remote display of serial data of numeric & alpha-numeric format. These indicators are ideal for applications where multiple slave display units are required. The indicators utilise DPM's ASCIIbus protocol for easy implementation into almost any system. The indicators come with a choice of either RS-232 input or RS-485 input for bus systems. The display may be set to flash on and off whenever the indicator does not receive valid refresh data within a specified time period. Options include programmable analogue output, one, two, three or four alarms, BCD output and other options. The analogue output option is rangeable from the front pushbuttons. Selected options now feature ‘Plug & Play’ technology, allowing option boards to be ordered separately & field fitted when required.
The DPM9004 is a miniature space saving 92mm x 92mm x 26mm DIN-rail mount programmable load cell transmitter. Configuration and field calibration is done via a notebook or desktop PC using the user-friendly software available from our website. Complete 3-way isolation is provided between power supply, input and output. The transmitter is designed for mV inputs from load cells, strain gauges and strain gauge pressure transmitters. The stable bridge excitation voltage is user selectable for normal or IS (barriered) applications, and can power four load cells with the standard 10V excitation. Sense feedback is included to compensate for cable loss. The precision instrumentation op-amp front end circuit ensures high accuracy & stability. The digital filter feature allows for a stable output in noisy systems. The isolated analogue output is configurable for industry standard 0-10V or 0-20 / 4-20mA signals. The RS-232 serial interface and a remote tare function is standard. The serial interface allows connections to remote computers and SCADA systems using DPM’s DIGIbus protocol. The RS-485 option allows up to 99 transmitters to be linked on the same bus. A feature of this programmable transmitter is the calibration method. Pre-calibrated ranges can be allocated zero and full scale values and these can be adjusted on site via a notebook to allow for dead-weight offset and a single point span calibration (test weight trim).
The DPM9244 is a miniature space-saving 92mm x 92mm x 26mm DIN-rail mount programmable load cell transmitter. Configuration and field calibration is done via a notebook or desktop PC using the user-friendly software available from our website. Complete 3-way isolation is provided between the power supply, input and output.
The DPM9006 is a miniature space saving 92mm x 92mm x 26mm DIN rail mount AC voltage or current programmable transmitter. The unit can accept voltages up to 500Vac/dc and currents up to 5Aac/dc, and converts them to an isolated 0-10V, 0-20mA or 4-20mA output. Configuration / programming of the unit is accomplished by using a notebook computer or a desktop PC using user-friendly software available from our website. This transmitter offers complete 3-way isolation between power supply, input and output. The power supply is 95-265Vac/dc as standard. The RS-232 serial interface is standard. The serial interface allows connections to remote computers and SCADA systems using DPM’s DIGIbus protocol. The RS-485 option allows up to 99 transmitters to be linked on the same bus.
4-Way 3-pole PT100/Thermocouple selector switch
6-Way 2-pole PT100/Thermocouple selector switch