Mechanical data
| Feature |
Technical data |
Additional information |
| Housing |
zinc die-cast |
|
| Wire design |
ø0.45 mm |
rustproof stainless steel, plastic-coated
|
| Extension force |
≥2 N |
T1 operating temperature
|
| |
≥11 N |
T2 working temperature
|
| Measured distance/ rope drum revolution |
100 mm |
|
| Absolute accuracy |
±0.35 % |
relating to measuring length (mm) |
| Cable length |
≤30 m |
4/20mA, MWIHP, MWIHP/R encoder type
|
| |
≤20 m |
P10; 0/10V; 0,5/4,5V encoder type
|
| Weight |
~0.32 kg |
|
Electrical data
Encoder potentiometer
| Feature |
Technical data |
Additional information |
| Power rating |
2 W at 70 °C |
|
| Resistance |
10 kΩ |
|
| Resistance tolerance |
±5 % |
|
| Linearity tolerance |
±0.25 % |
|
Transducer, power output
| Feature |
Technical data |
Additional information |
| Operating voltage |
10 … 30 V DC |
between I+ and I-, at ≤500 Ω load
|
| Output current |
4 … 20 mA |
(4/20mA; MWIHP)
|
Transducer, voltage output
| Feature |
Technical data |
Additional information |
| Operating voltage |
15 … 28 V DC |
at 3 mA without load (0/10V)
|
| |
8 … 28 V DC |
at 3 mA without load (0,5/4,5V)
|
| Output voltage |
0 … 10 V DC |
ILoad ≤10 mA
|
| |
0.5 … 4.5 V DC |
ILast ≤10 mA (0,5/4,5V)
|
| Resistance |
2 … 10 kΩ |
against GND
|
| Load |
≤15 mA |
|
*
Measurement transducers permit optimum adjustment of the output current and output voltage to the measuring range. The measurement transducer is pre-set at the works so that an output signal of 4 … 20 mA (MWI) or 0 … 10 V DC (MWU) is available.
System data
| Feature |
Technical data |
Additional information |
| Repeat accuracy |
±0.15 mm |
|
| Travel speed |
≤1 m/s |
|
Ambient conditions
| Feature |
Technical data |
Additional information |
| Ambient temperature |
-10 … 80 °C |
T1 |
| |
-40 … 80 °C |
T2 |
| Protection category |
IP65 (encoder part)
|
EN 60529 |