SPECIFICATIONS
|
PARAMETER
|
VALUE
|
UNIT
|
Standard capacities (Emax)
|
0.25, 0.5, 1, 2, 3.5, 5, 10, 28, 60
|
t
|
Accuracy class according to OIML
|
NTEP IIIL
|
D3
|
C3(3)
|
C6(2)
|
|
Maximum no. of verification intervals (nlc)
|
10000
|
|
3000
|
6000
|
|
Minimum verification interval
|
|
|
Emax/10000
|
Emax/15000
|
|
Minimum verification interval type MR
|
|
|
Emax/20000(1)
|
Emax/28000
|
|
Rated output (=S)
|
2 (1.75 for 0.25 t, 2.05 for 10 t)
|
mV/V
|
Output accuracy for multiple LC systems
|
0.01
|
±% mV/V
|
Zero balance
|
1.0
|
±% FSO
|
Combined error
|
0.0200
|
0.0300
|
0.0230
|
0.0115
|
±% FSO
|
Creep error (30 minutes)
|
|
|
0.0245
|
0.0123
|
±% FSO
|
Temperature effect on zero
|
(0.0010)
|
(0.0010)
|
0.0070
|
0.0045
|
±% FSO/5°C (/°F)
|
Temperature effect on sensitivity (output)
|
(0.0008)
|
(0.0008)
|
0.0050
|
0.0025
|
±% FSO/5°C (/°F)
|
Minimum dead load
|
0
|
% Emax
|
Maximum safe overload
|
150
|
% Emax
|
Ultimate overload
|
300
|
% Emax
|
Maximum safe side load
|
100% up to 10 t
50% for 28 & 60 t
|
% Emax
|
Deflection at Emax
|
0.12–0.20
|
mm
|
Excitation voltage
|
5 to 15
|
V
|
Maximum excitation voltage
|
30
|
V
|
Input resistance
|
1110±50 (1100±50 for 0.25 t and 10 t)
1075±100 for 28 t
1350±100 for 60 t
|
Ω
|
Output resistance
|
1025±25 (1025±50 for 0.25 t and 10 t)
930±0.5 for 28 t
1175±0.5 for 60 t
|
Ω
|
Insulation resistance
|
≥5000 (20 for 28 and 60 t)
|
MΩ
|
Compensated temperature range
|
-10 to +40
|
°C
|
Operating temperature range
|
-30 to +70
|
°C
|
Storage temperature range
|
-50 to +80
|
°C
|
Element material (DIN)
|
Stainless steel 1.4542
|
|
Sealing (DIN 40.050 / EN60.529)
|
IP66 and IP68; IP69K available for 250 kg, 5 t and 10 t
|
|
Recommended torque on fixation bolts
|
12 to 14
|
N*m
|
ATEX opt. for potent. explosive atmospheres
|
II2G EEx ib IIC T4/T6, II2D, IIID T70 II3G nA II T4/T6
|
|
(1) Capacities of 28 and 60 ton Emax/15,000 approved to OIML C3 only
(2) 250 kg and 10 t capacities are approved to OIML C3 only. The maximum application range for 0.5 t is 0.75*Emax.
(3) The following accuracy classes are available (from 0.5 t to 10 t): C3MI6 and C3MI7.5. Minimum dead load output return is 1⁄2 Emax/6000 and 1⁄2 Emax /7500 respectively
FSO—Full-Scale Output
All specifications subject to change without notice.