{{image.AltTag}} {{image.AltTag}}
Default Image Default Image

{{details.product.ModelName}}

Sku: {{details.product.ModelNumber}}

Siko Setpoint display AP10T-with bus interface, for format part or tool change
{{details.product.PriceUnits}}
Please fill out this field...
Please enter a number...
Please enter at least 1...
Please enter at max 999999...

You purchased this item on {{details.product.OrderHistory[0].OrderDate | date : 'yyyy-MM-dd'}}

Setpoint display with communication interface visualizes instructions for the operator during product change or format changes. Readability is optimized for intuitive user prompting: The red/green LEDs indicate whether a format part change is required. With the help of the backlit display, designations or setpoint and actual value can be clearly displayed. The operator confirms the changeover using an acknowledgment button.
This means that faulty machine settings with the setpoint display AP10T can be avoided in the future, making flexible production machines more process-reliable.

Profile AP10T:

  • Setpoint display with bus interface without measurement of actual value
  • Large control key to confirm target value
  • Optimally readable backlit display
  • Two-line LCD-Display
  • Integrated RS485 interface, CAN bus as an option
  • User guidance via bicolor status LEDs
  • IP53 type of protection, IP65 as an option

Mechanical data

Feature Technical data Additional information
Housing reinforced plastic plug thread, nickel-plated brass/cover, metal ground connection
Color

black, RAL 9005

 
Weight ~0.09 kg  

Electrical data

Feature Technical data Additional information
Operating voltage 24 V DC ±20 %  
Current consumption ~30 mA

additional ~3 mA per LED when operated with LEDs

Power input ~0.72 VA Max. power supply of the power supply unit used: 100 VA.
The power supply used corresponds to SELV/Limited Energy (IEC 61010-1) or SELV/LPS (IEC 60950-1) or Class 2 (UL 1310).
Parameter storage 105 cycles also applies to calibration operations
Display/display range

6-digit LCD 14-segment, ~8 mm height

decimal points, 2 rows, (backlit LED red/white)

Status display

2x two-color LED (red/green)

acknowledgment status, configurable

Keys

acknowledgment, parameterization

 
Bus connection RS485; CANopen

no galvanic isolation

Type of connection

2x M8-plug connectors (A-coded)

4-pole, 1x socket, 1x pin

 

grounding via flat male tab 6.3 mm or terminal lug

 
System data
Feature Technical data Additional information
Approval UL UL 61010-1, File No. E503367

Ambient conditions

Feature Technical data Additional information
Ambient temperature 0 … 60 °C  
Storage temperature -20 … 80 °C  
Relative humidity   condensation inadmissible
EMC EN 61326-1 Industry immunity requirement, class B emission limit
Safety regulations DIN EN 61010-1 (VDE 0411-1), UL 61010-1 Limited power supply according to DIN EN 61010-1 Section 9.4.
Protection class II
Surge category II
Pollution level 2
Protection category IP53

EN 60529, only with mating connector (protection class not examined by UL)

  IP65

EN 60529, only with mating connector (protection class not examined by UL)

Shock resistance 500 m/s2, 11 ms

EN 60068-2-27

Vibration resistance 100 m/s2, 5 … 150 Hz

EN 60068-2-6

Ordering table

Feature Order data Specifications Additional information
Interface/protocol

AS3/09

RS485/SIKONETZ5  

CAN

CANopen  
 
Protection category

BIP53

IP53  

IP65

IP65  
 
Viewing window

CSF

front foil  

K

plastic impact protection
 

Ordering key

AP10T-A-B-EX-C-S