For more information, click here!
Pin assignment
Signal |
PIN |
Sin |
1 |
GND |
2 |
/Sin |
3 |
/Cos |
4 |
T+ |
5 |
Cos |
6 |
D+ |
7 |
T- |
8 |
+Ub |
9 |
D- |
10 |
config |
11 |
nc |
12 |

Industry 4.0
In most cases, data exchange with the magnetic encoders is limited to the exchange of process data. In addition to the process data, intelligent drives provide additional information that can be evaluated for condition monitoring up to predictive maintenance:
Process Data |
Smart Value |
Smart Function |
Actual position |
-- |
Plausibility monitoring |
Hint for mounting
Please ensure correct allignment of both system components to each other during mounting of sensor and magnetic ring.
A, Sensor/ring reading distance
(active measurement area) |
0.1 … 1.0 mm |
B, Lateral offset |
±1.5 mm |
C, Misalignment |
<±0.5° |

Symbolic sensor representation
Scope of delivery
- MSAC506
- Quick Start Guide