  • Display accuracy max. 1 μm
  • Repeat accuracy max. ±1 μm
  • High-contrast LCD, 12-digit LCD dot matrix
  • Incremental measurement and reset function
  • Direct reference/offset value input
  • Reference input
  • Works with sensor MS100/1
  • Option: serial interface RS232/RS485/switching output
  • Option: TG01 bench housing

Mechanical data

Feature Technical data Additional information
Housing design

built-in housing, plastic

switchboard cutout 92+0.8 x 45+0.6 IEC 61554

Electrical data

Feature Technical data Additional information
Operating voltage 24 V DC ±20 %  
  115 V AC ±10 %  
  230 V AC ±10 %  
Current consumption 70 mA

at 24 V DC

  20 mA

at 115 V AC

  10 mA

at 230 V AC

Display/display range

12-digit, LCD dot matrix, backlit

-9999999 ... 9999999
Switching outputs

with or without

2x 30 V ≤100 mA
Interface

without, RS232, RS485

 
Type of connection

connector

9-pole (supply, switching output, interface/reference connection)

 

mini-DIN

6-pole, 1x socket (MS100/1 sensor)

System data

Feature Technical data Additional information
Resolution 0.001, 0.01, 0.1, 1, 10 mm

programmable angle display

  0.001, 0.01, 0.1, 1 in  
System accuracy ±(0.01 + 0.01 x L) mm; L in m

at TU = 20 °C

Repeat accuracy ±0.001 mm

±1 increment

Travel speed ≤2 m/s  

Ambient conditions

Feature Technical data Additional information
Ambient temperature 0 … 50 °C  
Storage temperature -20 … 80 °C  
Relative humidity ≤95 % condensation inadmissible
EMC EN 61000-6-2 interference resistance / immission
  EN 61000-6-4

emitted interference / emission

Protection category

IP40 whole device

EN 60529
 

IP60 at the front with switchboard installation

EN 60529

Ordering table

Feature Order data Specifications Additional information
Operating voltage

A1

230 V AC  

2

115 V AC  

4

24 V DC  
 
Interface/protocol

BXX/XX

without  

S1/00

RS232 with standard protocol  

S3/00

RS485 with standard protocol  
 
Switching output

CSO

without  

SM

with only with XX/XX interface
 

Ordering key

MA100/2-EG-A-RM-B-C-S-BS

For more information, click here!

Pin assignment

Signal PIN
Reset 1
+24 V DC; ≤50 mA  (reference switch) 2
GND 3
nc 4
RS232 (RXD), RS485 (DÜB), actor A2 5
RS232 (TXD), RS485 (DÜA), actor A1 6
PE 7
N (230/115 V AC); 0 V (24 V DC) 8
L (230/115 V AC); +UB (24 V DC) 9