(1) 5 and 10 kg capacities are not approved by NTEP. 5 kg is not approved by OIML.
(2) Dmax = 0.75 * Emax
FSO—Full-Scale Output
SC-version: The rated output and the output resistance are balanced in such a way that the output current is calibrated to within 0.05% of a reference value. This allows easy parallel connection of the load cells.
All specifications subject to change without notice.
SPECIFICATIONS
|
PARAMETER
|
VALUE
|
UNIT
|
Standard capacities (Emax)
|
5, 10, 20, 30, 50, 100, 200, 350, 500 (1)
|
100, 200, 350, 500 (2)
|
kg
|
Accuracy class according to OIML R-60 /NTEP
|
NTEP IIIL
|
Non- Approved
|
C3
|
C4
|
C3MI7.5
|
|
Max. no. of verification intervals
|
10 000
|
|
3000
|
4000
|
3000
|
|
Min. verification interval (Vmin=Emax/Y)
|
|
Emax/15,000
|
Emax/15,000
|
Emax/15,000
|
|
MDLOR (Z=Emax/2*DR)
|
|
|
|
|
7500
|
|
Rated output (=S)
|
2
|
mV/V
|
Rated output tolerance
|
0.02
|
±mV/V
|
Zero balance
|
1.0
|
±% FSO
|
Combined error
|
0.0200
|
0.05000
|
0.0200
|
0.0170
|
0.0200
|
±% FSO
|
Non-repeatability
|
0.0100
|
0.0200
|
0.0100
|
0.0090
|
0.0100
|
±% FSO
|
Minimum dead load output return
|
0.0250
|
0.0500
|
0.0167
|
0.0125
|
0.0067
|
±% applied load
|
Creep error (30 minutes)
|
|
0.0600
|
0.0245
|
0.0184
|
0.0245
|
±% applied load
|
Creep error (20 - 30 minutes)
|
0.0300
|
0.0500
|
|
|
|
±% applied load
|
Temp. effect on min. dead load output
|
(0.0008)
|
0.0250
|
0.0047
|
0.0047
|
0.0047
|
±% FSO/5 °C (/°F)
|
Temperature effect on sensitivity
|
(0.0010)
|
0.0250
|
0.0050
|
0.0045
|
0.0050
|
±% applied load/5°C (/°F)
|
Minimum dead load
|
0
|
|
% Emax
|
Maximum safe overload
|
150
|
|
% Emax
|
Ultimate overload
|
300
|
|
% Emax
|
Maximum safe sideload
|
100
|
|
% Emax
|
Deflection at Emax
|
0.30±0.03
|
|
mm
|
Excitation voltage
|
5 to 12
|
|
V
|
Maximum excitation voltage
|
15
|
|
V
|
Input resistance
|
460±50
|
|
Ω
|
Output resistance
|
350±3.5
|
|
Ω
|
Insulation resistance
|
≥5000
|
|
M Ω
|
Compensated temperature range
|
–10 to +40
|
|
°C
|
Operating temperature range
|
–40 to +80
|
|
°C
|
Storage temperature range
|
–40 to +90
|
|
°C
|
Element material (DIN)
|
Stainless steel 1.4542
|
|
|
Sealing (DIN 40.050 / EN60.529)
|
IP66 and IP68
|
|
|
SC-Version (current calibration)
|
Standard
|
|
|
Recommended torque on fixation bolts
|
23 (70 for 350/500 kg)
|
|
N*m
|