The ToughSonic 14 ultrasonic sensor has a maximum range of 14 feet (4.3 meters). Like all ToughSonic sensors, it’s built for durability and ease of use in tough industrial environments. It’s fully submersible, corrosion resistant, shock resistant and all around tough. It’s also fully configurable with our SenixVIEW software. ToughSonic 14s include our famous “Teach” feature for push button configuration. This compact sensor is used around the world on remote liquid level systems, heavy equipment, factory automation applications and more. This is our most popular sensor.

For longer range applications or for chemically resistant sensors, please see our full line of ToughSonic and ToughSonic CHEM sensors.

  • Long range — small housing
  • Rugged construction, IP68 rated
  • Indoor or outdoor uses
  • Straight or tapered thread options
  • Two outputs plus serial data
  • Serial data-only models
  • Temperature compensation options
  • Push-button or PC configurable

Specifications

Maximum Range 14 feet (4.3 meters)
Optimum Range 4 inches to 10 feet
100 mm to 3 meters
Temperature -40° to 158° F (-40° to 70° C)
Humidity 0 to 100% operating
Protection NEMA-4X, NEMA 6P, IP68
Transducer Ruggedized piezoelectric
Compensation Temperature compensated (selectable in SenixVIEW)
Resolution Serial data: 0.0034 in. (0.086 mm)
Analog steps: 4099 (0-10 VDC),
3279 (4-20 mA)
Repeatability Nominal 0.2% of range @ constant temp. Affected by target, distance, environment
Update Rate 20 Hz (50 ms), SenixVIEW adjustable; affected by SenixVIEW filter selections

Specifications are subject to change without notice.

 

Outputs

Output #1 Default: 4-20 mA; SenixVIEW configurable
Alternate: Configure it as a switch output
Output #2 Default: Voltage, SenixVIEW configurable
Alternate: Configure it as a switch output
Voltage Output 0-10, 0-5 VDC or SenixVIEW configurable
10 mA maximum
4-20 mA
Current Loop
Current sourcing, SenixVIEW configurable
Maximum loop resistance 450Ω
Switch Output(s) Output #1 and/or #2 can be a switch
Each can be sinking (NPN) or sourcing (PNP)
Max ratings: 150 mA @ 40 VDC
Each has adjustable setpoint, polarity, hysteresis, window, time delays and more
RS-232 or
RS-485
Modbus & streaming protocols
9600-115200 baud (configurable)
8 data bits, 1 stop, no parity
RS-485 permits multi-sensor networks
Part number determines interface
SYNC feature Permits multiple sensors to operate in close proximity without cross-talk
Not usable concurrently with serial data

 

Mechanical

Housing 316 stainless steel for corrosion resistance
Usable in salt water, H2S environments
Mounting
(30 mm)
Through hole in bracket or panel
Two jam nuts included
Stainless & nylon brackets available
Adapters to 1-1/2 in and 2 in NPT available
Mounting
(1-in NPT)
Typically for tank mounting
Mates with 1-in NPT female thread
Attached Cable 6.5 feet (2 meters), PUR jacketed
Custom lengths available
Standard models: 6-wire shielded + drain
Serial data only models: 4-wire + drain, dual twisted shielded pair
Total Weight 30 mm: 10.4 oz. (0.29 kg)
1-in NPT: 14.2 oz. (0.40 kg)
Weights include 2 m cable

 

For more information, click here!

Manual