The quick exposure time of only 90 μs makes the high speed IR thermometer CT 4M the perfect sensor for measuring fast processes. Due to its short measuring wavelength and a temperature range from 0°C to 500 °C, the pyrometer optris CT 4M, is suitable for measurements of metals, metal oxides, ceramics or materials with unknown or changing emissivity.

The electronics box of the measuring device allows a flexible terminal device through selectable analog outputs as well as various optional digital interfaces.

  • Exposure time: 90 μs
  • Temperature range: 
    0°C to 500°C
  • Spectral range: 2.2 µm - 6.0 µm

Applications: 

The ultra-fast optris CT 4M features a response time of only 300 µs and is thus ideally suited for fast high-volume production and packaging processes (eg. PET preform temperature monitoring) and high-speed traffic safety applications like hot axle box detection on railways. Its wavelength of 2.2 µm to 6.0 µm allow for low-temperature measurements of metas, metal oxides, ceramics and materials with unknown or changing emissvity.

Measurement specifications

  • Temperature range (scalable via programming keys or software):
    0°C ... 500°C (4ML) 
  • Spectral range: 2.2 µm - 6.0 µm
  • Optical resolution (90 % energy): 10:1
  • System accuracy1) (at ambient temperature 23 ± 5 °C):
    ± (0.3 % of reading + 2 °C)
  • Repeatability (at ambient temperature 23 ± 5 °C):
    ± (0.1 % of reading + 1 °C)
  • NETD2): 120 mK
  • Temperature coefficient3): ±0.05 K/ K or ±0.03 %/ K
  • Exposure time: 90 μs (90 %)
  • Response time: 300 μs (90 %)
  • Emissivity / Gain (adjustable via programming keys or software):
    0.100 - 1.100
  • Transmissivity / Gain (adjustable via programming keys or software):
    0.100 - 1.100
  • Signal processing (parameter adjustable via programming keys or software, respectively): Peak hold, valley hold, peak picker, average; extended hold function with threshold and hysteresis
  • Software/App: optris CompactPlus Connect / IRmobile

General specifications

  • Environmental rating: IP 65 (NEMA-4)
  • Ambient temperature: 
    sensing head: 0 °C ... 70 °C
    electronics: 0 °C ... 70 °C
  • Storage temperature: 
    sensing head: – 40 °C ... 85 °C
    electronics: – 40 °C ... 85 °C
  • Relative humidity: 10 - 95%, non-condensing
  • Vibration (sensor): IEC 60068-2-6 / -64
  • Shock (sensor): IEC 60068-2-27 (25 G and 50 G)
  • Weight: 
    sensing head 40 g 
    electronics 420 g

Electrical specifications

  • Outputs / analog (2x): 0/4 - 20 mA, 0-5/10 V, thermocouple K, alarm
  • Output / alarm: 24 V / 50 mA (open collector)
  • I/O Pins (3x): flexible programming as in- or output: external emissivity adjustment, ambient temperature compensation, uncommitted value, trigger (reset of hold functions), alarm output (open collector 24 V/ 50 mA)
  • Relay (optional): 2 x 60 V DC/42 V ACeff; 0.4 A; optically isolated
  • Digital interfaces: built-in USB-interface, optional: RS232, RS485, Ethernet
  • Output impedances: 
    mA max. 500 Ω 
    mV min. 100 kΩ load impedance 
    thermocouple 20 Ω
  • Cable length: 3 m, 8 m, 15 m
  • Power supply: 8-30 V DC / 5 V USB / max. 1.2 W

1) ε = 1, response time 1 s
2) At time constant 1 ms and TObj = 50 °C
3) For ambient temperatures >10 °C, whichever is greater

Versions

Part number: temperature range / spectral range / optics / max. ambient temperature / cable length

  • OPT-CT-4M-LSFCB3:
    0-500°C / 2.2 μm  - 6.0 μm / 10:1 / 70°C / 3 m cable
  • OPT-CT-4M-LCFCB3:
    0-500°C / 2.2 μm  - 6.0 μm / 10:1 CF lens / 70°C / 3 m cable

1) ε = 1, response time 1 s
2) At time constant 1 ms and TObj = 50 °C
3) For ambient temperatures >10 °C, whichever is greater