Deadweight Tester / Pressure Balance Hydraulic, max. 1200 bar (16000 psi)
{{details.product.PriceUnits}}
Please fill out this field...
Please enter a number...
Please enter at least 1...
Please enter at max 999999...

You purchased this item on {{details.product.OrderHistory[0].OrderDate | date : 'yyyy-MM-dd'}}

Proven primary pressure standard
Deadweight Tester / Pressure Balances are the most accurate instrument available on the market for the calibration of electronic or mechanical pressure measuring instruments. The direct measurement of the pressure (p = F / A), as well as the use of high-quality materials, enable a very small measurement uncertainty, in conjunction with excellent long-term stability of 5 years (recommended in accordance with German Calibration Service DKD/DAkkS).
The deadweight tester/pressure balance has therefore been used for years in factory and calibration laboratories in national institutes, research laboratories and in industry.

Stand-alone operation
Due to its integrated pressure generation and the pure mechanical measuring principle, the model LR-Cal LDW-HK is ideal for on-site use for maintenance and service.

Basic principle
Pressure is defined as the quotient of force and area. The core component of the model LR-Cal LDW-HK is therefore a very precisely manufactured piston-cylinder-system, which is loaded with masses in order to generate the individual test points.
The masses applied are proportional to the target pressure and this is achieved through optimally graduated weights. As standard, these masses are manufactured to the standard gravity (9.80665 m/s²), though they can be manufactured to a specific location (gravity) and also UKAS (DAkkS)-calibrated.

Easy operation
The integrated dual-area spindle pump enables rapid filling of the test system and smooth pressure generation up to 1,200 bar. At the same time, the precisely adjustable spindle pump also serves for fine pressure adjustment. A control schematic for pressure generation on the instrument base facilitates quick and easy operation.

As soon as the measuring system reaches equilibrium, there is a balance of forces between the pressure and the mass load applied. The excellent quality of the system ensures that this pressure remains stable over several minutes, so that the pressure value for comparative measurements can be read without any problems, or also so that more complex adjustments can be carried out on the item under test.

Compact instrument design
The LR-Cal LDW-HK is also particularly notable for its compact dimensions, which are not altered during operation since the spindle runs within the pump body.
With its compact dimensions, the exceptionally robust ABS plastic housing and the low weight associated with these, the LR-Cal LDW-HK is also particularly suited to on-site applications.

Deadweight Tester (Pressure Balance, Primary Standard for Pressure), hydraulic,
pressure ranges from 1...120 bar to 10...1,200 bar and 10...1,600 psi to 100...16,000 psi.
Accuracy (total uncertainty) ±0.05% or 0.025% of measured value.

Features:

  • Primary standard for defining the pressure scale in a range up to 1,200 bar hydraulic
  • Reference instrument for factory and calibration laboratories for the testing, adjustment and calibration of pressure measuring instruments
  • The complete, stand-alone system, also suitable for on-site use

Special Features:

  • Total measurement uncertainty to 0.025% of the measured value
  • Factory calibration includes traceability to national standard; with UKAS calibration possible as an option
  • High long-term stability with recommended recalibration cycle every five years
  • Masses manufactured from stainless steel can be adjusted to local gravity
  • Compact dimensions
Pressure range "bar" 1) [bar] 1...120 2.5...300 5...700 10...1,200
Required masses [kg] 41 50 58 50
Smallest step 2)
standard mass set
[bar] 1 2,5 5 10
Nominal cross-sectional area
of the piston
[in²] 1/16 1/40 1/80 1/160
Pressure range "psi" 1) [psi] 10...1,600 25...4,000 50...10,000 100...16,000
Erforderliche Massen [kg] 38 47 58 47
Smallest step 2)
standard mass set
[psi] 10 25 50 100
Nominal cross-sectional area
of the piston
[in²] 1/16 1/40 1/80 1/160
Accuracy
Standard 3) [% of
measured
value]
0,05
Option 3) [% of
measured
value]
0,025
Pressure transmission medium Hydraulic fluid based on VG22 mineral oil (0.5 l included in scope of delivery)
Material
Piston  Tungsten carbide
Cylinder  Tungsten carbide
Set of masses Stainless steel, non-magnetic
Weight
Piston-cylinder system [kg] 2.4
"bar"-mass set, incl. bell jar [kg] 41.5 50.5 58.5 50.5
"psi"-mass set, incl. bell jar [kg] 47.5 47.5 58.5 47.5
Optional carrying case for set
of masses (2 pcs. required)
[kg] 5.8
Dimensions
Optional carrying case for set
of masses (2 pcs. required)
[mm] W 400 x D 310 x H 310

1) Theoretical starting value; corresponds to the pressure value generated by the piston or the piston and its make-up weights (bei their own weight). To optimise the operating characteristics more weights should be loaded.

2) The smallest pressure change value that can be achieved based on the standard weight set. To reduce this, a set of trim masses is also available, see Accessories.

3) The accuracy from 10% of the measuring range is based on the measured value. In the lower range, a fixed error based on 10% of the range applies.

4) Measuring uncertainty assuming reference conditions (ambient temperature 20°C, air pressure 1,013 mbar, relative humidity 40%). Corrections mus be made if required.

LR-Cal LDW-HK Specification instrument base

Connection for piston-cylinder system:   3/4" BSP male
Test item connection:   1/2" BSP female thread, free-running, incl. adapter set to 1/4" BSP and 3/8" BSP female threads
Wetted parts:   Austenitic stainless steel, high tensile brass, nitrile rubber
Pressure transmission medium:   Hydraulic fluid based on VG22 mineral oil (0.5 l included in scope of delivery)
Reservoir volume: [cm³] 170
Weight instrument base: [kg] 13.5
Weight optional storage case for the base: [kg] 8.5
Permissible operating temperature: [°C] 18...28
Dimensions of the base: [mm] W 401 x D 397 x H 155

LR-Cal LDW-HK Approvals + certificates

  • CE-Conformity:
    Pressure equipment directive 97/23/EC (Module A)
  • Factory certificate of calibration traceable to national standard
    Optional UKAS (DAkkS) certification

LR-Cal LDW-HK Scope of delivery + Options

Scope of Delivery:

  • Base, with adjustable feet
  • Dual-area spindle pump for filling, pressure generation and fine adjustment
  • Piston connection with 3/4" BSP male thread
  • Test item connection with 1/2" BSP female thread, loose union connection
  • Adapter set for test item connection, 1/2" BSP male to 1/4" BSP female and to 3/8" BSP female
  • Piston-cylinder system with overhang (bell jar)
  • Set of masses manufactured to standard gravity (9.80665 m/s²)
  • Tool and maintenance set
  • Manual in English and German language
  • Factory calibration certificate, traceable to national standard

Options:

  • System with increased accuracy to 0.025%
  • Set of masses manufactured to local gravity
  • Storage cases for the base, mass set and the piston-cylinder system
  • UKAS calibration certificate
Order-Code Description Image
LDW-FMS-F1 The weights included in the standard mass set are ideally suited for everyday use.
If smaller intermediate values need to be generated, we recommend using a set of trim masses.

Set of trim masses, class F1
1 x 50 g, 2 x 20 g, 1 x 10 g, 1 x 5 g, 2 x 2 g, 1 x 1 g,
1 x 500 mg, 2 x 200 mg, 1 x 100 mg, 1 x 50 mg,
style="line-height: 1.3em;">2 x 20 mg, 1 x 10 mg, 1 x 5 mg, 2 x 2 mg, 1 x 1 mg>
 
LDW-FMS-M1 Set of trim masses, class M1
1 x 50 g, 2 x 20 g, 1 x 10 g, 1 x 5 g, 2 x 2 g, 1 x 1 g,
1 x 500 mg, 2 x 200 mg, 1 x 100 mg, 1 x 50 mg,
2 x 20 mg, 1 x 10 mg, 1 x 5 mg, 2 x 2 mg, 1 x 1 mg
 
LDW-HK-KOFFER-MS Set of 2 carrying cases for set of masses  
LDW-HK-KOFFER-BM Storage case for instrument base  
LDW-ADAPTER-BSP "BSP" adapter set for 1/2" BSP male test item connector to
1/8" BSP, 1/4" BSP, 3/8" BSP and 1/2" BSP female
 
LDW-ADAPTER-NPT "NPT" adapter set for 1/2" BSP male test item connector to
1/8" NPT, 1/4" NPT, 3/8" NPT and 1/2" NPT female
 
LDW-ADAPTER-M "Metric" adapter set for 1/2" BSP male test item connector to
M12 x 1.5 and M20 x 1.5 female
 
LDW-PAS-G12 Test item connection, 3/4" BSP female to 1/2" BSP female, loose union connection,
to use the deadweight tester as pressure comparator with 2 test item connectors
 
CPB5000-WA90 90° angle connection, for test items with back mounting connection  
LDW-TV-M-0700 Separator, to separate 2 liquid media by a diaphragm, max. 700 bar  
LDW-TV-M-1200 Separator, to separate 2 liquid media by a diaphragm, max. 1,200 bar  
LDW-HK-R-SET Sealing set for instrument base  
CPB5000-FLUID Operating fluid (mineral oil based hydraulic oil, 1 litre)  
LDW-HK-W-SET SPARE: tool set consists of open-ended spanner, BSP adapter, replacement seals, pointer removal device and pointer press-on tool