{{image.AltTag}} {{image.AltTag}}
Default Image Default Image

{{details.product.ModelName}}

Sku: {{details.product.ModelNumber}}

Keller Series PD-39X-Ei differential pressure transmitters
{{details.product.PriceUnits}}
Please fill out this field...
Please enter a number...
Please enter at least 1...
Please enter at max 999999...

You purchased this item on {{details.product.OrderHistory[0].OrderDate | date : 'yyyy-MM-dd'}}

The differential pressure transmitters of the PD-39X-Ei series measure the pressure difference indirectly using two absolute pressure sensors. The dual-sensor design with numerical differential formation also outputs the line pressure values via the digital RS485 interface and guarantees a high overload resistance. The additional analog current or voltage output is primarily used to output the differential pressure range, which is freely rangeable within the line pressure range.

Intrinsically safe – suitable for use in explosive atmospheres.

Pressure Ranges 0…3 to 0…300 bar
Accuracy ±0,05 %FS
Total Error Band ± 0,1 %FS @ -10…80 °C
Temperature Range -40…90 °C
Line Pressure 0…3 to 0…300 bar
Interfaces RS485, 4…20 mA, 0…10 V
Special Characteristics Line pressure measurement