Hollow Shaft Encoder, dual channel and zero ref.The IG06 incremental encoder features a low-cost design with through hollow shaft and can be mounted easily.
The pressure test pump LR-Cal LPP 08 is used to generate pressure and vacuum for checking, adjusting and calibrating mechanical and electronic pressure measuring instruments by comparative measurements in the low-pressure and vacuum range. The pressure tests may be carried out in laboratories, workshops or on-site at the measuring point.
If the instrument to be tested and a sufficiently accurate reference measuring instrument are connected up to the pressure test pump, the same pressure is applied to the two measuring instruments when the pump is operated. By comparing the two measure values at random pressure values, the accuracy can be verified or the unit under test can be adjusted.
The LR-Cal LPP 08 is a pneumatic pressure test pump for low-pressure ranges up to 8 bar with a change-over switch to vacuum down to -850 mbar. Despite its compact dimensions, the pressure test pump is easy to operate and allows for the exact generation of the required test pressures. The maximum pressure or vacuum achievable depends on the attached test volume. The smooth-running pressure generation and the integrated fine adjustment valve allow a safe and precise setting of very small positive resp. negative pressure values in the range of mbar.
The unit under test and the reference instrument can be easily connected with the supplied accessories.
Included in the scope of standard delivery:
Compatible with many common handwheelsScale 86.8mm, reinforced plastic housing either dust-tight, oil filled or waterproof, scale and pointer
Geared Potentiometers - heavy duty ratios 0.25 to 550:1Potentiometer output with three CAM switches
The infrared cameras optris PI 400i / PI 450i are the smallest thermographic cameras in their class. Being equipped with a measurement speed of 80 Hz and an optical resolution of 382 x 288 pixels they provide real-time thermographic images in high speed.
The IR camera PI 450i is, due to its thermal sensitivity of 40 mK, specifically suited for the detection of slightest temperature differences, making it indispensable in quality control of products and in medical prevention.
The compact and high-performance infrared cameras offer a temperature range of -20°C up to 900°C, being optionally upgradeable up to 1500 °C. They can be delivered with exchangeable optics, industrial thermal imager equipment and they come with an extensive license-free thermography software package.
The DPM9006 is a miniature space saving 92mm x 92mm x 26mm DIN rail mount AC voltage or current programmable transmitter. The unit can accept voltages up to 500Vac/dc and currents up to 5Aac/dc, and converts them to an isolated 0-10V, 0-20mA or 4-20mA output. Configuration / programming of the unit is accomplished by using a notebook computer or a desktop PC using user-friendly software available from our website. This transmitter offers complete 3-way isolation between power supply, input and output. The power supply is 95-265Vac/dc as standard. The RS-232 serial interface is standard. The serial interface allows connections to remote computers and SCADA systems using DPM’s DIGIbus protocol. The RS-485 option allows up to 99 transmitters to be linked on the same bus.
Ultramodern welding techniques and advances in the miniaturization of electronic circuits now make it possible to manufacture a pre-insulated, piezoresistive micro-transmitter with properties that were no more than a dream 10 years ago. The circuit is based on the PromComp principle which KELLER offered in a separate version as a laboratory device 20 years ago when it attained accuracy of 0,1 %FS over a temperature range of 100 K. In those days the electronic circuitry was the size of a cigar box, but now it can be accommodated on a print that is a mere 12 mm in diameter. Although this digital component is only slightly more expensive to produce than an analog circuit, it allows a piezoresistive sensor to be calibrated to an accuracy of 0,5 %FS over a potential temperature range of 100 K. A temperature sensor divides the temperature range into fields with a width of 1,5 K each. Two values are assigned to each field in an EEPROM: one value for the zero point and another for the amplification, determined by mathematical interpolation in the calibration process. During operation, the corresponding values are ‚switched in’ at the relevant temperatures. The electronics make it possible to assign up to 120 fields so that a temperature range of 180 K can be covered. The 100 K restriction for series 21 PY is due to the sensor This means that more or less any temperature can be the ‚calibration temperature’ for these transmitters. Calibration and temperature errors within a temperature field are within ± 0,2 %FS. The remainder of the error bandwidth of ± 0,5 %FS can be attributed to linearity and stability errors. So it’s goodbye to the days when sensor engineers had to struggle every day with TKN (zero point) and TKG (gain/amplification) problems. The 21 PY product line is outstanding due to its extreme ruggedness towards electromagnetic fields. The limits of the CE standard are undercut by a factor of up to 10 with conducted and radiated fields, thus making this product ideal for use in harsh industrial environments.
The Y-line transmitters have an extremely small temperature error. This is achieved using an additional circuit containing a temperature sensor that subdivides the temperature range into fields that are 1,5 Kelvin (K) wide. The TK zero and TK compensation values are calculated for each field and programmed into the additional circuit. During operation, these values are fed into the analogue signal path depending on the temperature. Each temperature is the "calibration temperature" for this transmitter. The Series 23 (S)Y/25 Y product line is outstanding due to its extreme ruggedness towards electromagnetic fields. The limits of the CE standard are undercut by a factor of up to 10 with conducted and radiated fields.
4-Way 3-pole PT100/Thermocouple selector switch
The DPM4001, four digit LED Universal Process Indicator, can be applied to most process variables with analogue & digital inputs. This high accuracy, high-quality panel meter is designed for accurate measurement & display of pressure, level, flow, frequency, DC voltages or currents & revolutions per minute. Options include linearisation, analogue output and set-points up to a total of four. The display & analogue output is rangeable from the front pushbuttons. Excitation is standard & is link selectable for 2-wire / 3-wire transmitters, encoders & potentiometer input.
The portable dry metal block temperature calibrator model LR-Cal PULSAR-35Cu is used as temperature source and reference instrument for checking and calibrating of all kind of temperature measuring instruments, e.g. thermometer, thermostats, etc.
The LR-Cal PULSAR-80Cu temperature calibrator is a compact instrument used to calibrate temperature probes, thermometers, thermostats and temperature mesuring sensors. The considerable size makes it suitable for calibrations of probes with large insertion lengths.The LR-Cal PULSAR-80Cu temperature calibrator consists of a metal block (80 mm diameter x 300 mm depth) heated by a resistance which winds around the outer surface of the block. A hole with 60 mm diameter and 275 mm depth is made in the block for the apprpriate reduction inserts.The LR-Cal PULSAR-80Cu is equipped with a counter-current forced air cooling system which keeps the temperature at the upper part of the well low. This system enables to check even very short probes, without heating the connecting head or the handgrip.The instrument is equipped with a PID microprocessor controller with a resolution up to 0.01°C, allowing the setting of the standard of measurement to °C, °F or K and programming of ascent or descent ramps, and storage of thermostats' operative temperature.
Geared Potentiometers - light duty ratios 0.25 to 550:14-20 mA output with three CAM switches, solid shaft
Universally applicable wire-actuated encoder with measuring lengths of max. 12000 mm, robust construction as well as precise and safe wire guidance, geared up for attaching the most diverse types of rotary encoders with a 58 mm standard flange.
For small SIKO handwheelsScale 51.7mm, reinforced plastic housing either dust-tight, oil filled or waterproof, scale and pointer
The Series 1000 and 2000 are a range of extra large 3 to 5 digit LED array displays, 125 mm digit height, designed to be used in process / temperature / weighing applications where high visibility and distant viewing is required. Using high intensity wide angle LED's in an IP65 enamelled steel housing ensures clear viewing distances of greater than 50 metres. For high ambient temperature conditions, an optional special coated glass window is available.Typical applications include downtime, time and production control in large factories, the indication of load cell inputs / crane overload protection, process signals such as temperature, pressure, level, and AC or DC voltages and currents.For electrical specifications, input signal details, as well as the terminal connector assignments in the Extra Large Display, see the individual indicator operating manuals (e.g. Model 4001). Standard DPM indicators are used and internally fitted for the internal signal conversion for the Extra Large Displays. (Models ending in a 2)
The IG07 is a robust incremental encoder with through hollow shaft, which is nearly indestructible even under the harshest ambient conditions.Shaft Encoders: Heavy Duty AluminumHollow Shaft Encoder
Ultrasonic flow meters of the type-series FLOMIC FL3085 are intended for measurement and storage of data of instantaneous flow rate and total volume of the liquid passed through the metering point in fully flooded piping of large sizes. Of the measured fluid it is only required that it allows for undisturbed propagation of ultrasonic waves.The high measurement accuracy is achieved thanks to the calibration of the flow meters performed on a test rig. The FLOMIC FL3085 flow meters do not require an external power source. They have equipped by internal battery and they can be installed anywhere without availability of external power, the guaranted battery life time is 4 years.The electronic accessories of the meter make possible, apart from measurement and visualization of the data on instantaneous flow rate and aggregate volume of the fluid passed through the meter, storage of the data measured in regular intervals in own data logger, and data communication via standard electrical outputs to a master control system.
FLOMIC FL3005 are ultrasonic flow meters for convenient measurements of instantaneous flow rate and flow volume values on big diameters pipelines up to 2000mm; the measured data are easy to read, and the meter itself is very reliable and requires only simple maintenance procedures. FLOMIC FL3005 are installed directly to existing pipeline and theoretical calibration is made after instalation.They have equipped by internal battery and they can be installed anywhere without availability of external power.
Hollow Shaft EncoderThe IG06 incremental encoder features a low-cost design with through hollow shaft and can be mounted easily.