The Model 9400 is a Miniature space saving 92 x 92 x 26 mm DIN rail mount AC/DC voltage dual channel process power supply. The Model 9400 is a Miniature space saving 92 x 92 x 26 mm DIN rail mount dual channel process power supply. The outputs are galvanically isolated from each other as well as the input power supply. The 9400 outputs are regulated to 24V +/- 5% and current limited to 38mA. The 9400 outputs also contains an LED indication for correct operation or to indicate a current limit / short circuit condition. The 9400 also has a jumper setting to increase the current limit to 100mA per channel. The outputs can also be paralled together to increase the overall current if needed.
The DPM9006 is a miniature space saving 92mm x 92mm x 26mm DIN rail mount AC voltage or current programmable transmitter. The unit can accept voltages up to 500Vac/dc and currents up to 5Aac/dc, and converts them to an isolated 0-10V, 0-20mA or 4-20mA output. Configuration / programming of the unit is accomplished by using a notebook computer or a desktop PC using user-friendly software available from our website. This transmitter offers complete 3-way isolation between power supply, input and output. The power supply is 95-265Vac/dc as standard. The RS-232 serial interface is standard. The serial interface allows connections to remote computers and SCADA systems using DPM’s DIGIbus protocol. The RS-485 option allows up to 99 transmitters to be linked on the same bus.
Configuration and field calibration is done via a notebook computer or desktop PC using user-friendly software available from our website. This transmitter offers complete 3-way isolation between power supply, input and output. The inputs are programmable to accept thermocouples of type J, K, N, R, S, T & W5, RTD’s of type Pt100 or Ni100, mV inputs up to 52mV, 0-20mA / 4-20mA inputs, volt inputs up to 10V, potentiometer inputs, and frequency inputs from NPN / PNP proximity switches. Integral 2-wire transmitter power is supplied as standard with the unit, as well as a precision reference for potentiometer inputs. The analogue output is programmable for 0-20mA / 4-20mA or 0-10V output. The power supply is 95-265V ac/dc as standard. The RS-232 serial interface is standard. The serial interface allows connections to remote computers and SCADA systems using DPM’s DIGIbus protocol. The RS-485 option allows up to 99 transmitters to be linked on the same bus. The unit can also accept an ASCII based serial input signal for conversion to an analogue output signal. The lineariser feature is standard and the user can select s-curve, sphere, square-root extraction or off (no linearisation)
The DPM9004 is a miniature space saving 92mm x 92mm x 26mm DIN-rail mount programmable load cell transmitter. Configuration and field calibration is done via a notebook or desktop PC using the user-friendly software available from our website. Complete 3-way isolation is provided between power supply, input and output. The transmitter is designed for mV inputs from load cells, strain gauges and strain gauge pressure transmitters. The stable bridge excitation voltage is user selectable for normal or IS (barriered) applications, and can power four load cells with the standard 10V excitation. Sense feedback is included to compensate for cable loss. The precision instrumentation op-amp front end circuit ensures high accuracy & stability. The digital filter feature allows for a stable output in noisy systems. The isolated analogue output is configurable for industry standard 0-10V or 0-20 / 4-20mA signals. The RS-232 serial interface and a remote tare function is standard. The serial interface allows connections to remote computers and SCADA systems using DPM’s DIGIbus protocol. The RS-485 option allows up to 99 transmitters to be linked on the same bus. A feature of this programmable transmitter is the calibration method. Pre-calibrated ranges can be allocated zero and full scale values and these can be adjusted on site via a notebook to allow for dead-weight offset and a single point span calibration (test weight trim).
The DPM9240 miniature space saving 92 x 92 x 26 mm DIN rail mount Universal Programmable Transmitters. Configuration and field calibration is done via a notebook computer or desktop PC using user-friendly software available from our website. This transmitter offers complete 3-way isolation between power supply, input and output. The inputs are programmable to accept thermocouples of type J, K, N, R, S, T & W5, RTD’s of type Pt100 or Ni100, mV inputs up to 52mV, 0-20mA / 4-20mA inputs, volt inputs up to 10V, potentiometer inputs, and frequency inputs from NPN / PNP proximity switches. Integral 2-wire transmitter power is supplied as standard with the unit, as well as a precision reference for potentiometer inputs. The analogue output is programmable for 0-20mA / 4-20mA or 0-10V output. A 24Vdc isolated power supply is supplied as standard. The RS-232 serial interface is standard. The serial interface allows connections to remote computers and SCADA systems using DPM’s DIGIbus protocol. The RS-485 option allows up to 99 transmitters to be linked on the same bus. The unit can also accept an ASCII based serial input signal for conversion to an analogue output signal. The lineariser feature is standard and the user can select s-curve, sphere, square-root extraction or off (no linearisation)
The DPM9244 is a miniature space-saving 92mm x 92mm x 26mm DIN-rail mount programmable load cell transmitter. Configuration and field calibration is done via a notebook or desktop PC using the user-friendly software available from our website. Complete 3-way isolation is provided between the power supply, input and output.