Siko Magnetic sensor MSA111C
Product Information
- Max. resolution 1 μm
- Repeat accuracy 2 μm
- System accuracy up to 10 μm
- SSI, RS485, DRIVE-CLiQ output circuits
- Additional analog real-time signal output Sin/Cos 1 VSS for highly dynamic control (SSI/RS485)
- Signal period 1 mm
- Certified according to SIL2 (DRIVE-CLiQ) for safety applications
- Industry 4.0 ready
Mechanical data
| Feature | Technical data | Additional information |
|---|---|---|
| Housing | zinc die-cast | |
| Sensor/band reading distance | ≤0.3 mm | (without masking tape on magnetic tape) |
Electrical data
| Feature | Technical data | Additional information |
|---|---|---|
| Operating voltage | 4.5 … 30 V DC |
reverse polarity protected (RS485, SSI) |
| 10 … 30 V DC |
reverse polarity protected, SELV/PELV (DRIVE-CLiQ) |
|
| Power input | ≤1.2 W |
RS485, SSI |
| ≤1.6 W |
DRIVE-CLiQ |
|
| Temperature sensor input |
external sensor, type KTY84 |
DRIVE-CLiQ (12-pole plug connector) |
| SSI clock speed input | ≤750 kHz | caution: max. clock rate depends on cable length |
| Output voltage | 1 VPP |
RS485, SSI |
| Period length of sin/cos output | 1000 µm |
RS485, SSI |
| Interface |
SSI, RS485, DRIVE-CLiQ |
|
| Real-time requirement |
speed-proportional signal output |
sin/cos output (RS485, SSI) |
| Cycle time | <25 µs |
RS485, SSI |
| <30 µs |
DRIVE-CLiQ |
|
| Type of connection | M12 plug connector (A-coded) |
12-pole, 1x pin (RS485, SSI, DRIVE-CLiQ with temperature sensor input) |
| M12 plug connector (A-coded) |
8-pole, 1x pin (DRIVE-CLiQ) |
System data
| Feature | Technical data | Additional information |
|---|---|---|
| Pole length | 1 mm | |
| Resolution | 1 µm | |
| System accuracy | ±10 µm |
at TU = 20 °C |
| Repeat accuracy | ≤2 µm |
unidirectional |
| Measuring range | ≤4000 mm | |
| Travel speed | ≤2 m/s |
static operation (RS485, SSI) |
| ≤10 m/s |
dynamic operation (sin/cos) (RS485, SSI) |
|
| ≤5 m/s |
DRIVE-CLiQ |
|
| Functional safety |
SIL 2 according to EN 61508 |
as well as EN 61800-5-2 category 3, PL d according to EN ISO 13849-1: 2008 (DRIVE-CLiQ) |
| Failure rate | 413 year(s) |
at 40 °C (MTTFd), DRIVE-CLiQ |
| 3.82 x 10-9
/h |
at 40 °C (PFH), DRIVE-CLiQ |
|
| Error detection | 92.2 % |
at 40 °C (DCavg), DRIVE-CLiQ |
| Safe position | <6 mm |
DRIVE-CLiQ |
Ambient conditions
| Feature | Technical data | Additional information |
|---|---|---|
| Ambient temperature | -30 … 85 °C |
RS485, SSI |
| -30 … 80 °C |
DRIVE-CLiQ |
|
| Storage temperature | -40 … 85 °C | |
| Expansion coefficient | (11 ±1) x 10-6/K | |
| Relative humidity | 100 % | condensation admissible |
| EMC | EN 61000-6-2 | interference resistance / immission |
| EN 61000-6-4 |
emitted interference / emission |
|
| Protection category | IP67 | EN 60529, mating connector mounted |
| Shock resistance | 500 m/s2, 11 ms |
EN 60068-2-27 |
| Vibration resistance | 100 m/s2, 5 … 150 Hz |
EN 60068-2-6 |
Ordering table
| Feature | Order data | Specifications | Additional information |
|---|---|---|---|
| Interface |
ASSI |
RS422 | |
|
DQ |
DRIVE-CLiQ | ||
|
RS485 |
SIKONETZ3 | ||
| Temperature sensor |
BK |
without cable | |
|
E |
for external temperature sensor | only with DQ interface | |
| Connector position |
CH |
horizontal | |
|
V |
vertical | ||
| Software |
DS |
standard | with SSI, RS485, DQ without SIL2 |
|
SW1 |
SIL2-compliant | Only with DO. SIL2-compliance only ensured with ZB3053 mounting kit; it is imperative that the kit is ordered as well! |
|
Ordering key
MSA111C-A-B-C-D
Pin assignment
RS485, SSI
| RS485 | SSI | PIN |
|---|---|---|
| adjust | adjust | 1 |
| D+ | D+ | 2 |
| D- | D- | 3 |
| nc | T- | 4 |
| +UB | +UB | 5 |
| /sin | /sin | 6 |
| sin | sin | 7 |
| /cos | /cos | 8 |
| cos | cos | 9 |
| config | config | 10 |
| nc | T+ | 11 |
| 0V | 0V | 12 |
DRIVE-CLiQ without temperature sensor input
| Signal | PIN |
|---|---|
| +24 V | 1 |
| DÜA | 2 |
| RXP | 3 |
| RXN | 4 |
| GND | 5 |
| TXN | 6 |
| TXP | 7 |
| DÜB | 8 |
DRIVE-CLiQ with temperature sensor input*
| Signal | Pin |
|---|---|
| +24 V | 1 |
| Tsens+ | 2 |
| GND | 3 |
| TXN | 4 |
| TXP | 5 |
| NC | 6 |
| RXN | 7 |
| RXP | 8 |
| DÜA | 9 |
| Tsens– | 10 |
| nc | 11 |
| DÜB | 12 |
* works only with a temperature sensor connected
Industry 4.0
In most cases, data exchange with the magnetic encoders is limited to the exchange of process data. In addition to the process data, intelligent drives provide additional information that can be evaluated for condition monitoring up to predictive maintenance:
| Process Data | Smart Value | Smart Function |
|---|---|---|
| Actual position | Temperature | Plausibility monitoring |
Hint for mounting
When mounting sensor and magnetic tape, please be careful to align both system components correctly. The arrow marks on the tape and sensor must point in the same direction when mounting the components.
| A, Sensor/tape reading distance | ≤0.3 mm |
| B, Lateral offset | +0.4 mm, -0.2 mm |
| C, Alignment error | <±1° |
| D, Longitudinal tilt | max. sensor/tape A reading distance must never be exceeded. |
| E, Lateral tilt | max. sensor/tape A reading distance must never be exceeded. |

symbolic sensor representation
Scope of delivery
- MSA111C
- Mounting instructions
- distance gage
For more information, click here!
- Data sheet
- Quick Start Guide
- Installation Instructions
- Mounting instructions software RS485
- Mounting instructions software SSI
- Mounting instructions DRIVE-CLiQ software
- Mounting instructions SIL2 software
- 3D-CAD model
- Press Release
- Press Release
- Press Release
- Certificate DRIVE-CLiQ with SIL2
- Certificate of DRIVE-CLiQ Standard
- Certificate DRIVE-CLiQ with external temperature sensor input
- EU-conformity declarations