Siko AP05
Product Information
- Electronic position indicator with bus interface
- Backlit two-row LCD
- Display of target and actual value displays with integrated alignment
- User guidance through status LEDs
- Hollow shaft with Ø 20 mm and clamping ring made of stainless steel
- Enhanced shock resistance owing to protective display glass
- Integrated RS485 interface, CAN bus as an option
- Robust sensor technology unit thanks to magnetic scanning
- Mechanically compatible with the AP04 and DA04 position indicators
- IP53 type of protection, IP65 as an option
- Industry 4.0 ready
Mechanical data
| Feature | Technical data | Additional information |
|---|---|---|
| Shaft |
plastic |
|
| Housing | reinforced plastic | plug thread, nickel-plated brass/cover, metal ground connection |
| Color |
black, RAL 9005 |
|
| Clamping ring |
stainless steel |
|
| Speed | ≤500 rpm | |
| Cable sheath |
PUR |
EX15 type of connection |
| Cable bending radius | ≥30 mm | permanently laid |
| Weight | ~0.07 kg |
Electrical data
| Feature | Technical data | Additional information |
|---|---|---|
| Operating voltage | 24 V DC ±20 % |
reverse polarity protected |
| Current consumption | ~30 mA | |
| Battery service life | ~8 year(s) | |
| Parameter storage | 105 cycles | also applies to calibration operations |
| Display/display range |
5-digit LCD 7-segment, ~6 mm height |
decimal points, 2 rows, special characters (LED backlit red/white) |
| Special character |
arrow clockwise, arrow conter-clockwise, incremental dimension, battery |
|
| Status display |
2x two-color LED (red/green) |
position status, configurable |
| Keys |
incremental measurement function, parameterizing, resetting |
|
| Bus connection | RS485; CANopen |
no galvanic isolation |
| Type of connection |
2x M8-plug connectors (A-coded) |
4-pole, 1x socket, 1x pin |
|
grounding via flat connector 6.3 mm |
System data
| Feature | Technical data | Additional information |
|---|---|---|
| Scanning |
magnetic |
|
| Resolution | 720 increments/revolution | displayed value/revolution freely configurable |
| Measuring range | ≤932067 revolution(s) |
coded |
Ambient conditions
| Feature | Technical data | Additional information |
|---|---|---|
| Ambient temperature | 0 … 60 °C | |
| Storage temperature | -20 … 80 °C | |
| Relative humidity | condensation inadmissible | |
| EMC | EN 61326-1 | Industrial immunity requirements, class B emission limit |
| Protection category |
IP53 |
EN 60529, in the fitted condition, with mating connector mounted |
| IP65 |
EN 60529, in the fitted condition, with mating connector mounted |
|
| Shock resistance | ≤500 m/s2, 11 ms |
EN 60068-2-27, half-sine, 3 axes (+/-), each 3 pulses |
| Vibration resistance | ≤100 m/s2, 10 … 2000 Hz |
EN 60068-2-6, 3 axes, each 10 cycles |

| Feature | Order data | Specifications | Additional information |
|---|---|---|---|
| Interface/protocol |
ACAN |
CANopen | |
|
S3/09 |
RS485/SIKONETZ5 | ||
| Hollow shaft/diameter |
B20 |
ø20 mm | |
|
… |
RH12, RH14, RH15, RH16 | reducing bushes | |
| Intermediate plate |
COZP |
without | |
|
ZP04 |
|||
|
ZP09 |
adaptation DA09S | ||
| Protection category |
DIP53 |
IP53 | |
|
IP65 |
IP65 | ||
| Type of connection |
EEX |
industrial connector | without cable |
|
E15X |
cable outlet | ||
| Software |
FS |
standard software | |
|
SW04 |
compatible to AP04-CAN | ||
|
SW05 |
compatible to AP04-SN5 | ||
|
SW06 |
compatible to AP04-SN3/4 | ||
Ordering table
| Feature | Order data | Specifications | Additional information |
|---|---|---|---|
| Interface/protocol |
ACAN |
CANopen | |
|
S3/09 |
RS485/SIKONETZ5 | ||
| Hollow shaft/diameter |
B20 |
ø20 mm | |
|
… |
RH12, RH14, RH15, RH16 | reducing bushes | |
| Intermediate plate |
COZP |
without | |
|
ZP04 |
|||
|
ZP09 |
adaptation DA09S | ||
| Protection category |
DIP53 |
IP53 | |
|
IP65 |
IP65 | ||
| Type of connection |
EEX |
industrial connector | without cable |
|
E15X |
cable outlet | ||
| Software |
FS |
standard software | |
|
SW04 |
compatible to AP04-CAN | ||
|
SW05 |
compatible to AP04-SN5 | ||
|
SW06 |
compatible to AP04-SN3/4 | ||
Ordering key
AP05-A-B-A-C-D-E-F
For more information, click here!
Pin Assignment
Interfaces
| RS485 | CAN | PIN |
|---|---|---|
| TxRx-/DÜB | CANL | 1 |
| TxRx+/DÜA | CANH | 2 |
| +24 V DC | +24 V DC | 3 |
| GND | GND | 4 |
Industry 4.0
In most cases, data exchange with the position indicators is limited to the exchange of process data. In addition to the process data, intelligent displays provide additional information that can be evaluated for condition monitoring up to predictive maintenance:
| Process Data | Smart Value | Smart Function |
|---|---|---|
| Actual position | Battery voltage | Battery change planning |
| Target position | Speed | Overload |
Scope of delivery
- AP05
- Mounting instructions