Magnetic sensor MS500
Product Information
- Profile MS500:
- Compact design of sensor and connector
- To be connected to MA502 or MA506
- Works with MB500/1 magnetic tape, MR500 magnetic ring, MBR500 magnetic tape ring
- Reading distance ≤2 mm
Mechanical data
| Feature | Technical data | Additional information |
|---|---|---|
| Housing | aluminum red | L design |
|
steel |
F design |
|
| Sensor/band reading distance | 0.1 … 2 mm | |
| Cable sheath | PUR, PVC | 6-wire ø5.1-0.2 mm |
Electrical data
| Feature | Technical data | Additional information |
|---|---|---|
| Operating voltage | supply via measurement display / downstream electronic unit | |
| Current consumption | supply via measurement display / downstream electronic unit | |
| Type of connection |
mini-DIN |
6-pole, 1x pin (for MA502, MA506, MA523/1 or AS510/1 translation module) |
System data
| Feature | Technical data | Additional information |
|---|---|---|
| System accuracy | depending on downstream electronic unit | |
| Repeat accuracy | depending on downstream electronic unit | |
| Travel speed | ≤5 m/s depending on downstream electronic unit |
Ambient conditions
| Feature | Technical data | Additional information |
|---|---|---|
| Ambient temperature | 0 … 60 °C | |
| Storage temperature | -20 … 70 °C | |
| Relative humidity | 100 % |
condensation admissible (sensor head) |
| Protection category | IP67 |
EN 60529 (sensor head) |
| Shock resistance | 2000 m/s2, 11 ms | EN 60068-2-27 |
| Vibration resistance | 200 m/s2, 50 Hz … 2 kHz | EN 60068-2-6 |
Ordering table
| Feature | Order data | Specifications | Additional information |
|---|---|---|---|
| Design |
AL |
rectangular | |
|
F |
round | ||
| Cable sheath |
BPVC |
||
|
PUR |
oil-resistant | ||
| Cable length |
C… |
00.2 … 20.0 m, in intervals of 1 m | |
Ordering key
MS500-A-B-C
For more information, click here!
Hint for mounting
| A, Sensor/tape reading distance | ≤2 mm |
| B, Lateral offset | ±2 mm |
| C, Alignment error | ±3° |
| D, Longitudinal inclination | ±1° |
| E, Lateral inclination | ±3° |
The length of the cable between the sensor and connector cannot be subsequently increased or decreased.
Scope of delivery
- MS500
- User information
- Fastening set