DPM5015
Product Information
The DPM5015, 5 ½ (-199999 to 199999), LED Dual Channel Process Indicator can be applied to many applications which require a dual input and a single display eg. temperature and humidity monitoring. Each channel is individually setup for zero , span, input type and more. The unit boasts a number of useful mathematical functions such as addition, subtraction, multiplication and division. The display as well as alarms, analogue out and peak hold can be selected using channel A, Channel B and the above mentioned mathematical functions.
Options include linearisation, analogue output and set-points up to a total of four. Excitation is standard and link selectable for 2-wire / 3-wire transmitters and a potentiometer input.
Selected options now feature ‘Plug & Play’ technology, allowing option boards to be ordered separately & field fitted when required.
- Front panel IP65 / NEMA 4 / UL Type 4 rating,
- 5 ½ Digit : -199999 to 199999
- Dual channel process inputs of 0 – 20mA, 4 – 20mA and Volt input
- Dual 24Vdc supply for 2 / 3 wire transmitters
- Low cost – high performance design
- Built in mathematical features such as adding (summing) / subtracting
- (Differential),multiplication and division of both inputs
- Keypad lockout standard
- Meets European EMC directive 89/336/EEC & Low Voltage directive 73/23/EEC
- Customizable to suit your requirementsts
General
| Display | 5 ½ Digit (-199999 to 199999) |
| Display | Colour : Red |
| Display | Size : 14.2mm |
| Display | Type : 7 Segments LED |
| Enviromental | Humidity : < 85% non-condensing |
| Enviromental | Operating temperature range : -10 to +50°C |
| Enviromental | Service temperature range : -15 to +60°C |
| Enviromental | Storage temperature range : -40 to +80°C |
| Front panel rating | IP 65 / NEMA 4 / UL Type 4 with supplied o-ring seal |
| Mounting | Panel Mounted |
| Physical | Cut out Size : 48mm x 96mm |
| Physical | Size : 48mm x 96mm x 147mm |
| Physical | Weight : approx. 385g (no options fitted) |
| Protection | UL94V-0 : Flame retardant ABS plastic housing |
| Regulatory compliance | Complies with EC Directives 89/336/EEC & 73/23/EEC |
| Supply | Standard : 95 to 265Vac/dc |
Excitation
| Link selectable for | 24Vdc (17-26V), current limited. (For 2-wire transmitters). 5Vdc ± 1%. Maximum 25mA. 2.5Vdc precision reference, 2mA maximum for potentiometer (2kO pot minimum). |
| Option | 24Vdc (17-26V), increased current capacity 100mA with option 3010. |
Serial Interface Options
| Capabilities – Asciibus protocol | continuous output approximately 5 x second |
| Capabilities – Asciibus protocol | output on demand via print button |
| Capabilities – Asciibus protocol | output on demand via serial request |
| Capabilities – Digibus protocol | Full remote control, except for field setup |
| Isolation to input | Optional, 1500V isolation (order option 3006) |
| Serial interface | RS -232 or RS -485, 2400, 4800, 9600 & 19200 baud |
Operation
| Memory retention | Full non-volatile operation |
| Specifications | Full digital with visual prompting in plain messages |
Analogue Input Ranges
| 0 – 10 V | Input impedance 500kO |
| 0 – 2 V | Input impedance 100kO |
| 0 – 20 mA | Input impedance 100O |
| 0 – 200 mV | Input impedance 100kO |
| 4 – 20 mA | Input impedance 100O |
| A/D conversion rate | Approximately 7 per second |
| A/D Type & resolution | 16 bit dual slope, 40 000 internal counts |
| Accuracy & linearity | 0.05% of full scale, ± 1 display count |
| Note | Other ranges on request |
| Note | These inputs are all standard and are link selectable, with programmable zero, span and decimal point. |
| Potentiometer | Input impedance 100kO |
| Power-up / self test time | 1 – 3 seconds |
| Settling time (frequency input) | 5 msec (no averaging) |
| Settling time (process inputs) | 0.5 seconds |
| Temperature coefficient | 20 ppm/°C typically |
| Warm up time | None required |
Analogue Outout Options
| Analogue output accuracy | 0.1% of full scale, 12-bits |
| Analogue output isolation | Optional, 1500V input/output isolation (order option 3006) |
| Analogue output temp. coefficient | 20 ppm / °C typically |
| Current analogue output load | 500O maximum (current is source, not sink) |
| Voltage analogue output load | 1kO minimum |
Setput Options
| Adjustable settings | Hysteresis, on delay, hi/lo, normally open/closed |
| Electro-mechanical relay | Form type: Form C (change-over contact) |
| Electro-mechanical relay | Rating: 250Vac, 30Vdc, 2A, power factor 1 |
| Solid- state relay | Form type: Form A (normally open contact) |
| Solid- state relay | Rating: 400Vac/dc, 0.5A, power factor 1 |
Power Supply
| Optional | 10V-30Vdc isolated switch mode power supply option (Option 3008), 5VA typical |
| Optional | 8V-30Vdc non-isolated dc power supply (Option 3028), 5VA typical |
| Optional | 95V-265Vac/dc switch mode power supply option (Option 3010), 5VA typical |
| Standard | 115 / 230Vac ± 10% (standard), link selectable, 50/60Hz, 5VA typical |
This product is available in the following options:
- DPM3000 – Lineariser (square root / sphere / & more)
- DPM3003 – 0 – 20mA / 4 – 20 mA analogue output
- DPM3006 – Isolated outputs (order with 3002/3/13)
- DPM3009 – Parallel BCD output (cannot be ordered with any alarm options, option 3006 or with option 3022)
- DPM3012 – Peak / valley hold
- DPM3014 – Auto zero (with remote zero)
- DPM3025 – Keypad lockout Standard
- DPM3026 – Display hold
- DPM3028 – 10 – 30Vdc non isolated dc supply
- Setpoint – Alarms – DPM3001P, DPM3001M, DPM3004P, DPM3004M, DPM3017P, DPM3017M, DPM3018P, DPM3018M
- Outputs – DPM3002, DPM3013
- Power Supply – DPM3008, DPM3010
- Displays – DPM3020