Shaft Encoders: Accessory M4 Mounting Flange
Shaft Encoders: Accessory Measuring wheel
Profile IV5800: -Resolution max. 5000 pulses/revolution -IP65 or IP66/IP67 type of protection -Robust bearing construction - -40 °C … +85 °C operating temperature - High shock and vibration resistance
Geared Potentiometers - light duty ratios 0.25 to 550:1 Potentiometer output, solid shaft
KOBOLD pressure sensors series PDD are cost effective electronic pressure switches with digital indication of actual pressure. Two switch points, on/off-switch delay and hysteris are within the measuring range programmable.
KOBOLD pressure transmitter series PDA are cost effective electronic presure transmitters with digital indication of actual pressure. An analogue output(0)4-20 mA is available for remote transmission of the measured value. The device is also available with a switch output as well
The KOBOLD URK model flowmeter/monitor works on the basis of the suspended float principle. It is sued for measuring the flow rate in closed line systems. The medium fl;ows from below throigh a glass measuring cone that gets wider on top. Thhus, the float is raised and indicates the respectie flow rate on the scale provided on the measuring cone.
The Kobold flowmeter model UTS works on the basis of the suspended float principle. It comes with a M 18 x 1.5 connection. The inflow of the medium is via 4 mm hole within this connection, whereas the outflow happens via six holes which are concentrically positioned around the inlet hole. This special connection is specifically made for UTS and provided with a special seal. This flowmeter can be optionally supplied with a special adapter G ¼ or ¼" NPT for horizontal installation. The use of this adapter is always recommended because of its special design. Especially in tight places, where conventional devices do not fit best because of their size, the UTS is an automatic choice. The device is suitable for monitoring gas burners (e. g. oxygen, hydrogen, methane, inert gases e.g. MIG welding) due to its low price and possibility of an easy measuring tube exchange. The armature is made of nickel plated brass or stainless steel with impact resistant polystyrene protection bulb.
Potentiometer output Wire-actuated encoder with analog output, potentiometric, current source or voltage output, with a measuring length of up to 6000 mm. Easy adjustment of the output signal to the actual measuring length via an integrated gear mechanism.
Current/Voltage output Wire-actuated encoder with analog output, potentiometric, current source or voltage output, with a measuring length of up to 6000 mm. Easy adjustment of the output signal to the actual measuring length via an integrated gear mechanism.
Geared Potentiometers - heavy duty ratios 0.25 to 550:1 4-20 mA output with three CAM switches
Geared Potentiometers - heavy duty ratios 0.25 to 550:1 Potentiometer output
Geared Potentiometers - heavy duty ratios 0.25 to 550:1 4-20mA output
Geared Potentiometers - light duty ratios 0.25 to 550:1 Potentiometer output with three CAM switches, solid shaft
Hollow Shaft Encoder, dual channel The IG06 incremental encoder features a low-cost design with through hollow shaft and can be mounted easily.
Induction flow meters of the FLONET FN20XX.1 type series are intended for professional application and measurement of flow rates of electrically-conductive liquids in water and heat-supply systems, food-processing and chemical industries. They meet the most demanding requirements on high measurement accuracy, long-term stability and hygienic standard. The converter provides for sensor energizing and processing of the sensor signals, and also offers functions of liquid batching control, detection of empty piping, internal meter status diagnostics, automatic counter cleaning and selection of flow units in data visualization. The flow meters have frequency, pulse and current outputs, as well as interfaces to the RS 232 and RS 485 communication lines.
The flow meter monitor PPS is a flow monitor for nominal pipe sizes greater than NW 32. Fluid flow (regardless of direction) deflects the paddle and over an eccentric movies a magnet fitted to a permanent magnet.
KOBOLD NBK bypass level indicators are used for continuous measurement, display and monitoring of liquid levels. The bypass tube is attached onto the side wall of the vessel.
The operation of the model KAL-.... electronic flow monitor is based on the calorimetric principle. The end face of the sensor is heated to a few degrees above the temperature of the flow medium. When the medium flows, the heat generated in the sensor is transferred to the medium, ie, the sensor is cooled. The cooling procedure is an accurate measure of the flow velocity. The sensor signal is compared with the reference data stored in a microcontroller. An alarm signal and/or an analogue signal (4-20 mA) that is proportional to the flow velocity is output if the actual flow velocity devices deviates from the desired flow velocity. The microcontroller allows the flow indicator to be easily calibrated and the temperature to be compensated.
OverviewApplicationsMore information The operation of the model KAL-... electronic flow monitor is based on the calorimetric principle. The end face of the sensor is heated to a few degrees above the temperature of the flow medium. When the medium flows, the heat generated in the sensoris transferred to the medium, ie, the sensor is cooled. The cooling procedure is an accurate measure of the flow velocity. The sensor signal is compared with the reference data stored in microcontroller. An alarm signal and/or an analogue signal (4-20mA) that is proportional to the flow velocity is output if the actual flow velocity deviates from the desired flow velocity. The microcontroller allows the flow indicator to be easily claibrated and the temperature to be compeansted.
Scale 86.8mm, reinforced plastic housing either dust-tight, oil filled or waterproof, scale and pointer, with additional digital counter