Product Details

Vishay-LC-5103

SKU:   LC-5103
Vishay-LC-5103: 
Double-Ended Beam Load Cell

5103 transducers are double-ended, center-loaded shear beam load cells. The 5103 is constructed of nickel-plated alloy steel. These products are suitable for tank weighing systems, low cost weighbridges, and axle weighers. A reliable sealing is ensured by the proprietary TRANSEAL potting compound and additional mechanical protection of the strain gage area. A specially designed mounting arrangement is available, providing the ideal solution for vessel / tank weighing

FEATURES

• Capacities: 5k to 250k lbs

• Low profile construction

• Nickel-plated alloy steel construction

• Certified to OIML R60 3000d, NTEP CoC—10000d

• Sealing: IP67 (DIN 40.050)

• Optional

❍ FM approved for use in hazardous locations

❍ ATEX versions are available for use in potentially explosive atmospheres

APPLICATIONS

• Platform scales

• On-board weighing

• Weighbridges

• Silo hopper weighing

SPECIFICATIONS PARAMETER UNIT VALUE Standard capacities (Emax) 2.3*, 4.5*, 9.1, 13.6, 18.2, 22.7, 27.2, 45.4, 68*, 91*, 113* t Standard capacities (Emax) 5k*, 10k*, 20k, 30k, 40k, 50k, 60k, 100k, 150k*, 200k*, 250k* lbs Accuracy class according to OIML / NTEP NTEP Non-Approved C3 Max. number of verification intervals (nlc) IIIL 10000 D3 3000 Minimum verification interval (vmin) Emax/10,000 Rated output (= S) 3.0 mV/V Rated output tolerance 0.003 ±mV/V Zero balance 1.0 ±% FSO Combined error 0.0200 0.0300 0.0200 ±% FSO Non-repeatability 0.0100 0.0100 0.0100 ±% FSO Minimum dead load output return 0.0250 0.0300 0.0167 ±% applied load Creep error (30 minutes) 0.0300 0.0245 ±% applied load Creep error (20 minutes) 0.030 0.0450 0.0053 ±% applied load Temp. effect on min. dead load output (0.001) 0.0140 0.0070 ±% FSO/5°C (/°F) Temperature effect on sensitivity (0.0008) 0.0070 0.0050 ±% applied load/5°C (/°F) Minimum dead load 0 % Emax Maximum safe overload 150 % Emax Ultimate overload 300 % Emax Maximum safe side load 100 % Emax Deflection at Emax 0.5/0.6/1.1/0.5/0.5/0.5/0.6/0.5/0.5/0.9/0.9 mm Excitation voltage 5 to 12 V Maximum excitation voltage 15 V Input resistance 700±7 Ω Output resistance 700±7 Ω Insulation resistance ≥5000 MΩ Compensated temperature range –10 to +40 °C Operating temperature range –40 to +80 °C Storage temperature range –40 to +90 °C Element material (DIN) Nickel-plated alloy steel Sealing (DIN 40.050 / EN 60.529) IP67 Recommended torque on fixation bolts 12 to 14 N*m

* Only 20k–100k lbs (9.1–45.4 t) capacities are OIML approved. FSO—Full Scale Output All specifications subject to change without notice.

For more information click here:

Datasheets

5103 - Double ended shear beam load cell.

Promotional Material

Other variants are available please do contact the office for more information.

 

Product Overview - Revere Load Cells

 

Capabilities Brochure - VPG Transducers Capabilities

 

Product Sheet - DCL08 Digital Load Cell Interface

 

Market Solutions - Force and Load Sensing for Industrial Vehicles

 

Capabilities Brochure - Strain Gage Bonding Services

 

Load Cells and Indicators - Databook

Technical Note

 

Technical Note VPG-07 - Wind Forces

 

Technical Note VPG-03 - Legal Metrology

 

Technical Note VPG-01 - Load Cell Technology

 

Technical Note VPG-08 - Load Cell Troubleshooting

 

Technical Note VPG-02 - Load Cell Accuracy in Relation to the Conditions of Use

 

Technical Note VPG-04 - Environmental Conditions

 

Technical Note VPG-05 - Current Calibration

 

Technical Note VPG-06 - Vessel Weighing