Sku: {{details.product.ModelNumber}}

incremental, interface, resolution 5 μm
{{details.product.PriceUnits}}
Please fill out this field...
Please enter a number...
Please enter at least 1...
Please enter at max 999999...

You purchased this item on {{details.product.OrderHistory[0].OrderDate | date : 'yyyy-MM-dd'}}
  • Parameters adjustable via DIP switches
  • Resolution up to 5 μm
  • Reference signal with intervals of 5 mm
  • Works with sensor MS500

Mechanical data

Feature Technical data Additional information
Housing

steel sheet

electrogalvanized

Electrical data

Feature Technical data Additional information
Operating voltage 24 V DC ±20 %

reverse polarity protected

  5 V DC ±5 %

no reverse polarity protection

Current consumption <70 mA  
Output circuit PP, LD (RS422)

switchover via DIP switches

Output signals A, A/, B, B/, 0, 0/  
Real-time requirement

speed-proportional signal output

 
Type of connection D-Sub

9-pole (supply and signal output)

 

mini-DIN

6-pole socket (sensor)

System data

Feature Technical data Additional information
Resolution 5, 10, 20, 25, 50, 100 µm

with quadruple evalution selectable via DIP switch

System accuracy ±(0.025 + 0.01 x L) mm, L in m

at TU = 20 °C (with MB500 and 0.05 mm accuracy class)

Repeat accuracy ±1 increment(s)  
Travel speed ≤20 m/s

sensor

Ambient conditions

Feature Technical data Additional information
Ambient temperature 0 … 70 °C  
Storage temperature -20 … 70 °C  
Relative humidity ≤95 % condensation inadmissible
EMC EN 61000-6-2 interference resistance / immission
  EN 61000-6-4

emitted interference / emission

Protection category IP40 EN 60529

Ordering table

Feature Order data Specifications Additional information
Operating voltage

A4

24 V DC reverse polarity protected

5

5 V DC no reverse polarity protection

Ordering key

AS510/1-A

Pin assignment

Signal PIN
A 1
A/ 2
GND (for output signal) 3
B 4
B/ 5
0 6
0/ 7
+UB 8
GND (for supply) 9

Scope of delivery

  • AS510/1
  • User information